© Titan Tool Inc. All rights reserved.
control Panel Indicators
The following is a description of the control panel indicators.
RAPID
CLEAN
Pressure
Indicator
Motor
Running
Indicator
Pressure Indicator
The pressure indicator shows the current operating pressure of the
sprayer. It has three different indications: blinking yellow, solid
yellow, and solid green.
Blinking yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 200 PSI. A blinking yellow pressure
indicator means:
• The sprayer is plugged in and turned “ON”
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a higher
pressure and the PrImE/SPray valve is in the
SPray position, either the spray tip is worn or the
sprayer is in need of service/repair.
Solid yellow
When the pressure indicator is solid yellow, the sprayer is operating
between 201 and 1900 PSI. A solid yellow pressure indicator means:
• The sprayer is at the proper pressure setting for spraying stain,
lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates one of
the following:
a. Tip wear Indicator — when spraying with latex or at high
pressure the solid yellow appears. This means the tip is worn
and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the sprayer is
put in the gun, the pressure indicator will turn from solid green
to solid yellow.
c. Fluid Section wear — if a solid yellow pressure indicator
appears when using a new tip and the pressure is set at
maximum, service may be required (worn packings, worn
piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is operating
between 1901 and 3300 PSI. A solid green pressure indicator means:
• The sprayer is at the proper pressure setting for spraying oil-
based and latex house paints
• The sprayer is operating at peak performance at a high
pressure setting
motor running Indicator
The Motor Running indicator is on when the motor is commanded to
run. This indicator is used by service centers to troubleshoot motor
problems.
NOTE: If the motor running and pressure indicators blink
alternately, it means the motor has overheated. Turn
pump OFF and allow to cool.
Digi-Trac™ control System Operation
The Digi-Trac™ Control System is an optional add-on that increases
the functionality of the sprayer. It is installed directly below the
pressure control knob on the control panel. It consists of a display
and four function keys. The display shows various menu screens that
allow the user to customize and monitor sprayer operation using the
function keys.
SET PSI
3000
ACTUAL PSI
2950
Display
Function
Keys
Function Keys
The function keys are numbered 1–4. Each key is labeled with an
additional function as well.
#1/menu Key
Pressing the #1 key scrolls through the available
menu screens or performs a function described
on the active menu screen.
#2/
p
Key
Pressing the #2 key performs a function
described on the active menu screen or increases
a value.
#3/
q
Key
Pressing the #3 key performs a function
described on the active menu screen or decrease
a value.
#4/Select Key
Pressing the #4 key selects the active menu
screen or performs a function described on the
active menu screen.
menu Screens
Several menu screens are available for the user to customize and
monitor sprayer operation. They include Main Screen, User Pre-
Sets, Volume Pumped, Job Volume, Unit Serial #, TImers, Job Timers,
Service Time, Security Code, Prime, and RAPID CLEAN.
main Screen
SET PSI
3000
ACTUAL PSI
2950
The Main Screen is the default screen for
the control system at sprayer startup.
Pressing the #2 key switches between PSI, Bar, and MPa units of
measure. Press the #1 key to scroll through the remaining menu
screens.
Volume Pumped Screen
VOLUME PUMPED
SELECT-4
MENU-1
The Volume Pumped screen shows the
total number of gallons or liters sprayed
by the sprayer.
GALLONS X
MENU-1
To select the Volume Pumped screen,
press the #4 key.
job Volume Screen
JOB VOLUME
SELECT-4
MENU-1
The Job Volume screen allows the user to
reset a gallon counter to track usage on
specific jobs.
JOB GAL
XXXX
RESET-3
MENU-1
To select the Job Volume screen, press
the #4 key.
unit Serial # Screen
UNIT SERIAL #
SELECT-4
MENU-1
The Unit Serial # screen shows the
sprayers serial number.
SER # XXXXXXXXXX
MENU-1
To select the Unit Serial # screen, press
the #4 key.