background image

2

© Titan Tool Inc.  All rights reserved.

This symbol indicates a hazardous situation,
which, if not not avoided could result in death or
serious injury.

To reduce the risks of fire or explosion, electrical
shock and the injury to persons, read and under-
stand all instructions included in this manual.  Be
familiar with the controls and proper usage of the
equipment.

HAZARD: INJECTION INJURY

A high pressure paint stream  produced by this
equipment can pierce the skin and underlying
tissues, leading to serious injury and possible
amputation.  See a physician immediately.

DO NOT TREAT AN INJECTION INJURY AS A SIMPLE
CUT!  Injection can lead to amputation.  See a physician
immediately.

The maximum operating range of the sprayer is 3300 PSI / 22.8
MPa fluid pressure.

PREVENTION:

• NEVER aim the gun at any part of the body. 
• Do not aim the gun at, or spray any person or animal.
• NEVER allow any part of the body to touch the fluid stream.

DO NOT allow body to touch a leak in the fluid hose.

• NEVER put your hand in front of the gun.  Gloves will not

provide protection against an injection injury.

• ALWAYS lock the gun trigger, shut the pump off, and

release all pressure before servicing, cleaning the tip or
guard, changing tip, or leaving unattended. Pressure will
not be released by turning off the motor.  The
PRIME/SPRAY valve or pressure bleed valve must be
turned to their appropriate positions to relieve system
pressure.  Refer to the PRESSURE RELIEF
PROCEDURE described in this manual.

• ALWAYS keep the tip guard in place while spraying. The

tip guard provides some protection but is mainly a
warning device.

• ALWAYS remove the spray tip before flushing or cleaning

the system.

• Paint hose can develop leaks from wear, kinking and

abuse.  A leak can inject material into the skin.  Inspect
the hose before each use.  Do not use hose to lift or pull
equipment.

• NEVER use a spray gun without a working trigger lock

and trigger guard in place.

• All accessories must be rated at or above 3300 PSI / 22.8

MPa.  This includes spray tips, guns, extensions, and hose.

• Do not leave the unit energized or under pressure while

unattended. When the unit is not in use, turn off the unit
and relieve the pressure in accordance with the
PRESSURE RELIEF PROCEDURE described in this
manual.

• Verify that all connections are secure before operating the

unit.  Unsecured parts may eject at great force or leak a
high pressure fluid stream causing severe injury.

• Always engage the trigger lock when not spraying.  Verify

the trigger lock is functioning properly.

NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury.  It is
important to treat the injury as soon as possible. DO
NOT delay treatment to research toxicity.  Toxicity is a
concern with some coatings injected directly into the
blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.

HAZARD: HAZARDOUS VAPORS

Paints, solvents, insecticides, and other materials can
be harmful if inhaled or come in contact with the body.
Vapors can cause severe nausea, fainting, or
poisoning.

PREVENTION:

• Use a respirator or mask if vapors can be

inhaled.  Read all instructions supplied with the
mask to be sure it will provide the necessary
protection. 

• Wear protective eyewear.
• Wear protective clothing as required by coating

manufacturer.

HAZARD: EXPLOSION OR FIRE 

Solvent and paint fumes can explode or ignite.
Property damage and/or severe injury can occur.

PREVENTION:

• Provide extensive exhaust and fresh air introduction to

keep the air within the spray area free from accumulation
of flammable vapors.  Solvent and paint fumes can
explode or ignite.

• Do not spray in a confined area.
• Avoid all ignition sources such as static electric

sparks, open flames, pilot lights, electrical
appliances, and hot objects.  Connecting or disconnecting
power cords or working light switches can make sparks.
Paint or solvent flowing through the equipment is able to
result in static electricity.

• Do not smoke in spray area.
• Fire extinguisher must be present and in good working

order.

• Place pump at least 25 feet (7.62 meters) from the spray

object in a well ventilated area (add more hose if
necessary).  Flammable vapors are often heavier than air.
Floor area must be extremely well ventilated.  The pump
contains arcing parts that emit sparks and can ignite
vapors.

• The equipment and objects in and around the spray area

must be properly grounded to prevent static sparks.

• Keep area clean and free of paint or solvent containers,

rags and other flammable materials.

• Use only conductive or grounded high pressure fluid hose.

Gun must be grounded through hose connections.

• For electric units — power cord must be connected to a

grounded circuit.

• Always flush unit into a separate metal container, at low

pump pressure, with spray tip removed.  Hold gun firmly
against side of container to ground container and prevent
static sparks.

• Follow the material and solvent manufacturer's warnings

and instructions.  Know the contents of the paints and
solvents being sprayed.  Read all Material Safety Data
Sheets (MSDS) and container labels provided with the
paints and solvents.  Follow the paint and solvent
manufacturer’s safety instructions.

• Use extreme caution when using materials with a

flashpoint below 70ºF (21ºC).  Flashpoint is the
temperature that a fluid can produce enough vapors to
ignite.

• Plastic can cause static sparks.  Never hang plastic to

enclose a spray area.  Do not use plastic drop cloths
when spraying flammable materials.

• Use lowest possible pressure to flush equipment.
• Do not spray onto pump assembly.

Important Safety Information

Read all safety information before 

operating the equipment.  Save these instructions.

Содержание 1140i

Страница 1: ...ayer Owner s Manual For professional use only NOTE This manual contains important warnings and instructions Please read and retain for reference NOTE This manual contains important warnings and instru...

Страница 2: ...injected directly into the blood stream Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable HAZARD HAZARDOUS VAPORS Paints solvents insecticides and other materials ca...

Страница 3: ...pressure to flush equipment Stay alert and watch what you are doing Do not operate the unit when fatigued or under the influence of drugs or alcohol For electric units Always unplug cord from outlet...

Страница 4: ...e on the hose tighten securely Make sure all airless hoses and spray guns are electrically grounded and rated for at least 3300 psi 22 8 MPa fluid pressure 4 Make sure the pressure control knob is in...

Страница 5: ...d section Painting 1 Place the siphon tube into a container of paint 2 Place the return hose into a metal waste container 3 Move the PRIME SPRAY valve down to the PRIME position 4 Turn the unit on and...

Страница 6: ...locked position 2 Turn the pressure control knob counterclockwise to its OFF position in the black zone 3 Unlock the gun by turning the gun trigger lock to the unlocked position Trigger lock in locked...

Страница 7: ...rayer hose and gun should be cleaned thoroughly after daily use Failure to do so permits material to build up seriously affecting the performance of the unit Always spray at minimum pressure with the...

Страница 8: ...1 Push the groove pin out of the valve handle 2 Remove the valve handle and the cam base 3 Using a wrench loosen and remove the valve housing assembly 4 Make sure the gasket is in place and thread the...

Страница 9: ...e the four motor shroud screws Remove the motor shroud 3 Release the tie wrap on the top of the baffle assembly and slip the baffle assembly down off of the motor 4 Loosen and remove the three electro...

Страница 10: ...ts until the connecting pin is visible below the slider housing 3 Turn off and unplug the unit Before proceeding follow the Pressure Relief Procedure outlined previously in this manual Additionally fo...

Страница 11: ...ng kit over the top of the piston rod 20 Insert the piston rod into the bottom of the upper housing through the lower packing through the upper packing and out through the upper seal retainer 21 Remov...

Страница 12: ...er tripped 1 Air in line 2 Insufficient pressure 1 No paint 2 Siphon strainer clogged 3 Sprayer gun filter clogged 4 Sprayer will not prime material too heavy 1 Air leak in system 2 Air leak in siphon...

Страница 13: ...ayer capacity 1 Worn tip 2 Tip may be chipped 1 Plugged worn or chipped tip 1 Leak in suction tube 2 Not enough hose 3 Tip too large or worn Solution 1 Increase pressure 2 Change to smaller tip 3 Clea...

Страница 14: ...n ou un sp cialiste en chirurgie reconstructive de la main DANGER MANATIONS DANGEREUSES Certains produits peintures solvants insecticides ou autres peuvent tre nocifs s ils sont inhal s ou entrent en...

Страница 15: ...ands vents Porter des v tements aptes prot ger la peau et les cheveux du produit utilis Ne pas utiliser le pistolet ou ne pas pulv riser de produits en pr sence d enfants proximit loigner les enfants...

Страница 16: ...revestimientos inyectados directamente en la corriente sangu nea Puede ser aconsejable consultar con un cirujano pl stico o un cirujano especialista en reconstrucci n de las manos PELIGRO VAPORES PEL...

Страница 17: ...uipo en todo momento No se asome ni se pare sobre soportes inestables Mantenga siempre la posici n firme y el equilibrio efectivos Use la presi n m s baja posible para enjuagar el equipo Mant ngase al...

Страница 18: ...551 Lock washer 2 7 858 625 Screw 2 8 800 328 Knock off nut 1 9 800 300 Fluid section assembly 1 10 451 241 Siphon tube 1 11 730 334 Hose clamp 1 Item Part Description Quantity 12 710 046 Inlet screen...

Страница 19: ...753 Connecting pin 1 17 800 202 Screw 2 18 800 276 Relay 1 19 704 229 Screw 1 20 765 327 Circuit breaker 1 21 800 075 Mounting plate 1 Item Part Description Quantity 22 800 077 Grommet 1 23 800 076 S...

Страница 20: ...packing with the side that has the o ring closest to the top of the packing facing up Install upper packing with raised lip facing down Raised Lip 22 Closer Top NOTE When repacking the fluid section...

Страница 21: ...des items 10 16 1 800 359 Lower packing insertion tool 800 273 Repacking kit includes items 2 3 5 8 11 13 14 18 20 and tool High Rider Cart P N 800 600 Item Part Description Quantity 1 800 280 Handle...

Страница 22: ...ess to Reset label 313 1848 Pressure control knob label 313 1867 Indicator lights label 313 1652 Titan front label 313 1906 Infinity logo label Low Rider Cart P N 800 590 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 23: ...likely to plug Liquid Shield Plus Cleans and protects spray systems against rust corrosion and premature wear Part No Description 314 483 4 ounce bottle 314 482 1 quart bottle Piston Lube Specially fo...

Страница 24: ...stallation substitution of non Titan component parts or tampering with the unit in a manner to impair normal operation Defective parts are to be returned to an authorized Titan sales service outlet Al...

Отзывы: