9
9)
Measure the distance from the back of the crossbar
mounting plate to the back of opposite mounting
plate and set the second column this distance
away from the first column that has already been
anchored. (As a reference - the distance between
the face of the columns should be +/- 117.50” at
the top and at the bottom of the lift) Using a tape
measure, measure diagonally from the face of
one column to the opposite face of the other, to
ensure that the columns are square (see below).
After confirming the dimensions, loosely install the
overhead crossbar assembly using the suppled
(8) bolts, washers, and nuts. Check front to back
and side to side plumb before drilling holes for
the anchor bolts. Again, it is extremely important
that these columns are perfectly plumb in both
directions. If you are confident in your dimensions,
drill the anchor bolt holes in the column, installing
anchors as you go. Check front to back and side
to side plumb before torqueing anchors to 85 ft-lbs. Use shims to plumb columns as
needed.
10) After both columns are properly torqued, tighten the (8) crossbar bolts.
11) In order to operate both lock latches from the power unit column, you will need to install
the Safety Release Cable. Start by loosening the bolt in the side of the lock mechanism
on the offside column and insert the cable though the hole and leave about 6-10” of
excess cable coming out. Snug the pinch bolt to secure the cable in place. Route the
other end of the cable under the safety release pulley in the column, then up and around
the safety release pulley at the top of the column. Continue to route the cable over to the
safety release pulley at the top
of the opposite column, then
down the inside of the column,
behind the carriage, until it
can be routed in between the
(2) safety release pulley’s on
the Power Unit side of the lift.
Loosen the bolt in the side of the
lock mechanism on the power
unit side column and feed the
rest of the cable though the lock
and pull all slack from the cable
prior to snugging the pinch bolt
back up. You can also install the
safety lock release handle to the
Main Side column but set the
ball handle aside for later in the
installation.
Содержание HD2P-13KCL
Страница 25: ...21 FIG 1 HD2P 13KCL 117 50 142 75 151 00 4 72 75 32 45 50 11 DIAGRAMS FIG 1 8...
Страница 26: ...22 FIG 2 HD2P 13KCL Column Anchor Bolts 3 4 6 25 Column 6 Concrete 3000PSI min Torque Nut...
Страница 32: ...28 FIG 8 CABLES HOSES...
Страница 35: ...31 NOTES...
Страница 38: ......
Страница 39: ...NOTES...