background image

3

ballasts and reflectors all plug into one unit. The digital based design of 

the controller allows for the Medusa™ to properly flip and control your 

grow lights. An easy to use trigger cord is plugged into the Apollo

®

 

Series timer (included) to control the switching between light banks. 

When powered ON, the Medusa™ Series Flipper is powering bank 

A by default. Once the trigger cord has been activated according the 

user defined timing pattern, the digital part of the controller goes to 

work. With precision timing, the Medusa™ Series flipper will turn OFF 

the power to the ballasts, switch the relays to bank B and then reapply 

power to the ballasts, lighting bank B. This controller also incorporates 

Titan Controls

®

 patented top off design for easy installation.

 

Instructions for Operation

• 

The Titan Controls

®

 Medusa™ - Four to Eight Light Digital Flipping 

Controller must be installed by a certified Electrician.

• 

Carefully remove the screws that attach the front cover and set the 

cover aside.

• 

Securely mount the Titan Controls

®

 Medusa™ - Four to Eight Light 

Digital Flipping Controller to the wall using the hardware included 

near your enclosure but away from any spray/mist/water, etc.

• 

Hardwire the controller into a confirmed 240 Volt – single phase 

power source.

• 

Connect the incoming 30 Amp – 240 VOLT neutral to the input 

power terminal block & L1, L2 to the circuit breaker. Also, ground 

the unit to a grounding lug located inside of the Titan Controls

®

 

Medusa™ - Four to Eight Light Digital Flipping Controller. 

• 

Verify that all of your connections are tight, set to torque 

specifications and that no loose wires are exposed.

• 

Apply power to the Titan Controls

®

 Medusa™ - Four to Eight Light 

Digital Flipping Controller and using a multi-meter or circuit tester, 

test all ballast outlets to verify voltage output levels are correct. Left 

outlets should be 240 Volts and right outlets should be 240 Volts.

• 

After verifying that all voltages are correct, deactivate the Medusa™ 

controller. Attach ballasts and reflectors that are to be controlled by 

the Titan Controls

®

 Medusa™ - Four to Eight Light Digital Flipping 

Controller. 

• 

Make sure all wires and cables are secured.

• 

Plug 24-hour timer into 120V AC circuit, then plug trigger cord set 

into timer. “Bank A” will operate in the ‘ON’ position and “Bank B” 

will operate in the ‘OFF’ position.

Caution

: Lamps are hot and should be allowed to cool before 

handling. 

Содержание Medusa 703380

Страница 1: ...Instruction Manual Product 703380 MEDUSA www titancontrols net...

Страница 2: ...air the unit Do not put paper clips tools etc into unit Possible electrocution may occur Verify your power sources are correct before connecting controller This controller is designed for INSIDE USE o...

Страница 3: ...all using the hardware included near your enclosure but away from any spray mist water etc Hardwire the controller into a confirmed 240 Volt single phase power source Connect the incoming 30 Amp 240 V...

Страница 4: ...ting outputs d Should you find that your circuit breaker keeps tripping check your panel breaker to verify that it is the correct amperage for the circuit load e Still having problems with the Titan C...

Страница 5: ...s provided through the factory or an authorized service representative This warranty shall apply to the United States including Alaska Hawaii and territories of the United States and Canada Defective...

Страница 6: ...___ _______________________________________________________ _______________________________________________________ __________________________ Send to your nearest location shipping address will be gi...

Страница 7: ...V AC Ballast 240V AC Ballast 240V AC Ballast 30 AMPS Input 240V AC Sun System Reflector Sun System Reflector Sun System Reflector Sun System Reflector Sun System Reflector Sun System Reflector Sun Sys...

Страница 8: ...Manuel d instructions Produit n 703380 MEDUSA MC www titancontrols net...

Страница 9: ...pareil Une lectrocution pourrait se produire S assurer que vos sources d alimentation sont correctes avant de brancher le contr leur Ce contr leur est con u pour une UTILISATION INT RIEURE seulement v...

Страница 10: ...se C blez le contr leur une source d alimentation monophas e confirm e de 240 volts Connectez le c ble d arriv e de 30 A 240 volts neutre au bornier d alimentation d entr e et les c bles L1 L2 au disj...

Страница 11: ...s constatez que votre disjoncteur continue se d clencher v rifiez le disjoncteur du panneau pour vous assurer qu il correspond au bon amp rage pour la charge du circuit e Vous prouvez toujours des pro...

Страница 12: ...nis l usine ou par un repr sentant de service autoris Cette garantie est applicable au Canada et aux tats Unis incluant l Alaska Hawa et les territoires des tats Unis et du Canada Les produits d fectu...

Страница 13: ...dition vous sera transmise en m me temps que le num ro d autorisation de retour de marchandise www titancontrols net Pour obtenir une assistance technique composez le 1 888 80 Titan ou le 1 888 808 48...

Страница 14: ...c a Entr e 30 A 240 V c a R flecteur Sun System MD R flecteur Sun System MD R flecteur Sun System MD R flecteur Sun System MD R flecteur Sun System MD R flecteur Sun System MD R flecteur Sun System M...

Страница 15: ..._____________________________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ 1...

Страница 16: ...______________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ___________...

Отзывы: