9
4
Night Output:
• The outlet can be used for a variety of devices that only require power at
night such as a circulation fan, heater or exhaust fan. This outlet activates
only during the nighttime period.
Recycling Timer Output:
• This output is for use with a pump, CO
2
regulator or generator, fan, etc.
BUTTON FUNCTIONS
There are 15 buttons located on the front faceplate of the unit that control all
functions. Pressing each button will display a function and/or current setting(s)
in the
green
LCD window. Some buttons are programmed to perform more
than one function.
The small
green
LED lights or status indicators located on the front panel will
light up to show the selected function when certain buttons are pushed.
UP
– Press this button to increase setting.
DOWN
– Press this button to decrease setting.
Enter/Reset
– Press button, hold for 3 seconds to enter new setting and to
reset the Min/Max range.
LIGHTING BUTTONS
Turn Lights ‘ON’ Time – Press button to set the ON Time for the Lighting
Outputs. The lights will turn ON once in a 24-hour time span.
Turn Lights ‘OFF’ Time – Press button to set the OFF Time for the Lighting
Outputs. The lights will turn OFF once in a 24-hour time span.
Hot Start Delay – Press button to set the time delay that allows the HID lamps
to cool before re-striking due to a power failure situation.
Override Light Timer – Press and hold this button for approximately 2 seconds
to manually activate and/or deactivate both of the Lights ON outputs, as well
as the Night Output. Press Override Light Timer button again to return to
normal operation.
Set Clock – Press button to set the current time of day.
Maximum Temp Setting – Press button to set the maximum temperature
level in your garden. This feature will shut off your Lighting Outputs if the
temperature in your garden exceeds the Maximum Temp Setting to protect it
from overheating your plants.
Installation Example:
Temperatur
e
Sensor
CO
2
Regulator
and T
ank
Contr
olling Lights with Heater
or
Cir
culation Fan,
& Pump
or
CO
2
Regulator