Electric Oven
User Manual
Electrical Connection
NOTICE //
This appliance must be connected only be a licensed electrician and installed in
accordance with the manufacturers instructions.
• Check that the power rating of the mains supply and of the sockets are suitable for the maxi-
mum power of the appliance as indicated on the specification plate. This oven must be
connected to a 220-240V 50Hz power supply. It is earthed via the cord and 15A plug.
• If the appliance is fitted with a supply lead and is not fitted with a plug, then permanently
connect it to the fixed wiring as follow:
• The “yellow/green” earth wire, which must be connected to terminal, has to be about
10mm longer than the other wires; the “blue” neutral wire has to be connected to the
terminal marked with letter N.
• “Black, brown, red” live wires have to be connected to terminal L. Mains connection can
also be made by fitting a double pole switch with a minimum gap between the contacts of
3mm, proportionate to the load and complying with the regulations in force.
• The yellow/green earth wire should not be controlled by the switch.
• The plug or a double pole switch used for mains supply connection should be easy to get at,
once the appliance is in position.
IMPORTANT // Position the mains supply cable so that it is never subjected to a temperature
which is more than 50°C above ambient temperature. The electrical safety of the appliance can
only be guaranteed when it has been correctly connected to an efficient earthed power supply,
as laid down in the regulations for electrical safety. The manufacturer cannot be held responsi-
ble for any damage to persons or objects due to lack of an earth connection. If the supply cord is
damaged, it must be replaced by the service agent or similarly qualified person in order to avoid