POSITIONING FOR GAS HOB
IMPORTANT //
This unit may be installed and used only in permanently ventilated rooms in
accordance with AS5601 (gas installations), local authority and any other statutory regulations.
The following requirements must be observed:
A The room must be fitted with a ventilation system which vents smoke and gases from
combustion to the outside. This must be done by means of a hood or electric ventilator
that turns on automatically each time the hood is operated.
b The room must also allow for the influx of the air needed for proper combustion. The flow
of air for combustion purposes must, not be less than 2m
3
/h per kW of installed capacity.
The supply of said air can be affected by means of direct influx from the outside through a
duct with a inner cross section of at least 100cm
2
which must not be able to be accidentally
blocked. Those appliances which are not fitted with a safety device to prevent the flame from
accidentally going out must have a ventilation opening twice the size otherwise required,
i.e. a minimum of 200 cm
2
(Fig. A). Otherwise, the room can be vented indirectly through
adjacent rooms fitted with ventilation ducts to the outside as described above, as long as the
adjacent rooms are not shared areas, bedrooms or present the risk of fire (Fig. b).
InsTallaTIOn
In a chimney stack or
branched flue. (Exclusively
for cooking appliances)
Directly to the outside
Examples of Ventilation
Holes for comburant air
- Fig. A
Detail A
Adjacent Room | Room to be vented
Enlarging the Ventilation
slots between the window
and floor - Fig. B
Содержание TGF30G
Страница 9: ...5 1 2 5 8 5 4 7 0 5 5 2 5 1 2 5 8 5 4 7 0 5 5 2 5 1 2 4 7 0 8 7 5 8 2 7...
Страница 16: ...pg 16 www tisira com tisira warrantyterms Conditions...
Страница 17: ...pg 17 tisira www tisira com PROOFOF PURCHASE...
Страница 18: ...pg 18 www tisira com tisira NOTES...
Страница 19: ...pg 19 tisira www tisira com NOTES...
Страница 20: ...pg 20 www tisira com tisira CONTACT DETAILS...