6
fig. 7
Make sure
, there is sufficient in the sand filter tank before priming the pump
If the pump does not prime, please observe the notes in the section trouble shooting.
Make sure
, all inlet and outlet valves are open, before priming the pump. Otherwise this could cause severe
damage of the pump.
6.4.
Fixed installation
For fixed installation of the electrical connection, make sure the plug can be easily reached and
is visible. For fixed installation the pump should be placed on a solid, horizontal surface.
Please note:
- If the filter is installed below the water surface, a shut-off valve should be installed. This pre-
vents unnecessary water flow during maintenance.
7. Electrical connection
The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp
edges. Defect power cords must be replaced immediately.
The values stated in the technical details have to correspond to the mains voltage. The person
responsible for the installation has to make sure that the electrical connection is earthed in
compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
If extension cables are used, their cross-section must not be smaller than that of rubber-
sheathed cables of the H07RN-F (3 x 1.0 mm²) short code. The mains socket and the plug-
and-socket elements have to be in splash-water-proof design.
The electrical installation must be done in accordance with the safety regulation for swimming
pools and in particular with standard HD 60364-7-702 and other local specifications regula-
tions.
8. Putting into operation
For the first operation it is recommended to fill the sand filter tank with water.
Avoid any dry-running
– operation of the pump without suction of water. This could cause an
overheating of the pump and severe damage of the device. In addition to this, there then very
hot water in the system, this can cause burning injuries and scalding. In case of an overheated
1.
inlet from the pump (marked “pump”)
2. outlet to the swimming pool
(marked “pool”) for normal filter operation
3.
outlet for waste water (marked „waste“) for back
wash
4. pressure gauge
18
Содержание 30310
Страница 50: ...Notizen notes note notas...
Страница 51: ...Notizen notes note notas...