background image

9

200/300 Series

 — CompX cabinet eLock Instructions

200/300 Series 

Cabinet eLock — Instructions

continued

200/300 Series 

Cabinet eLock — Manual Programming

Credential Menu

ADD CREDENTIAL

Note: There are two status levels; Supervisor and User. Each 

eLock can hold any combination of up to 3,000 Supervisors 

and Users.

Only 

Supervisors

 are allowed to 

ADD 

Users and Supervisors.

1.  Press “MENU.” 

LOGIN PLEASE 

will be displayed.

2. Scan valid credential or enter 4-14 digit PIN and Press

“ENTER.”

3. Press “DOWN” button to highlight 

CREDENTIAL MENU 

and

press “NEXT/SELECT.”

4. Highlight 

ADD CREDENTIAL 

and press “NEXT/SELECT.”

5.

CREDENTIAL TO ADD 

will be displayed. Scan new credential

or enter new 4-14 digit PIN and Press “ENTER.”

6.

Adding credential 

will be displayed.

7. Default status is 

User

. To change status to 

Supervisor 

press

the 

+

 button.

8. The new User/Supervisor will be added to the next available

slot number. To change the slot number, press “UP” and then

+/-

 to move to next available slot; or use the numeric keypad

to enter the desired slot number and press “NEXT/SELECT.”

9.

CREDENTIAL NAME ENTRY 

will appear. Press 2 - 9 for 

A - Z

;

press 1 for 

-

.

+

 or 

_

 ; press 0 for “

space

”; press and hold

0 - 9 for numbers. (Maximum number of allowed characters

is 14.)

10. Press “ENTER” when done. 

STORED

 will be displayed when

complete.

DELETE CREDENTIAL

Note: There are two status levels; Supervisor and User.
Only 

Supervisors

 are allowed to 

DELETE

 Users and 

Supervisors.

1.  Press “MENU.” 

LOGIN PLEASE 

will be displayed.

2. Scan valid credential or enter 4-14 digit PIN and Press

“ENTER”

3. Press “DOWN” button to highlight 

CREDENTIAL MENU 

and

press “NEXT/SELECT”

4. Highlight 

DELETE CREDENTIAL 

and press “NEXT/SELECT”

5.

Credential to Delete 

will be displayed. All of the occupied

slots along with the name (if one exists) will be listed. If

the status of the credential is a supervisor, an asterisk 

(*)

appears next to the slot number. Press “MENU” to re-sort

by slot number, alphabetically by name, or showing all

supervisors first.

6. Press ‘UP” / “DOWN” to scroll by line or 

+/-

 to scroll by

page to highlight credential to be deleted and press “NEXT/

SELECT.”

7. Press “UP” and “NEXT/SELECT” to delete. 

DELETED

 will be

displayed when complete.

8. Press “BACK/CANCEL” to return to 

CREDENTIAL MENU

.

VIEW CREDENTIAL

Note: There are two status levels; Supervisor and User.
Only 

Supervisors

 are allowed to 

VIEW 

Users and Supervisors.

1.  Press “MENU” 

LOGIN PLEASE 

will be displayed.

2. Scan valid credential or enter 4-14 digit PIN and Press

“ENTER.”

NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE A 4 - 14 

DIGIT PIN
To EXIT Passage Mode (re-lock the unit/extend the eLock 

latch bolt):

PIN CREDENTIAL

1. Enter a valid PIN (between 4 - 14 digits)
2. Press “ENTER.” 

EXITING PASSAGE MODE 

will flash on the

LCD and the latch bolt will extend.

CARD CREDENTIAL

If the eLock is equipped with a card reader (HID Prox, HID

iCLASS or Magstripe):

1. Present a valid card within range of the HID reader or slide

the magstripe card through the magstripe reader. 

EXITING

PASSAGE MODE 

will flash on the LCD and the latch bolt will

extend.

DUAL CREDENTIAL

If the User or Supervisor requires a dual credential:

1. Enter the primary valid PIN (for keypad credentials) and

press “ENTER” or present the valid card (for HID Prox, HID

iCLASS or Magstripe credentials). 

EXITING PASSAGE MODE

will flash on the LCD and the latch bolt will extend.

Содержание CompX eLock 200 Series

Страница 1: ...ion instructions for networked and stand alone eLocks please see the Help section in CompX s LockView v4 software 1 Dot matrix LCD 2 Network button blue LED 3 UP button 4 NEXT SELECT button 5 BACK CAN...

Страница 2: ...lation example Cabinet door installation shown eLock can also be installed on drawers Battery cable connector Integrated Wi Fi antenna cable included for 300 Series Wi Fi version 200 300 Series Cabine...

Страница 3: ...r mounting Drill 7 32 through hole 1 for mounting 2 1 WARNING Print this page and measure the line above It is ONE INCH LONG If it measures less than or more than one inch the template measurements al...

Страница 4: ...200 300 Series CompX cabinet eLock Instructions 4 TEMPLATE ON OPPOSITE PAGE...

Страница 5: ...3 Battery cable connector 4 2 5 mm AC adapter plug in adapter not included 5 Ground terminal 6 Dual eLatch connector Latch 2 if equipped one latch is included 7 Latch connector Latch 1 one latch is i...

Страница 6: ...it for through hole battery cable w 3 8 drill bit for through hole Wi Fi antenna cable 300 Series Wi Fi only w 7 32 drill bit for through holes to mount eLock display unit w T15 pin in Torx 6 lobe bit...

Страница 7: ...PIN CREDENTIAL 1 Enter a valid PIN between 4 14 digits and 2 Press ENTER CARD CREDENTIAL If the eLock is equipped with a card reader HID Prox HID iCLASS or a Magstripe 1 Present a valid card within ra...

Страница 8: ...SETUP mode PASSAGE MODE LockView software required To hold the latch bolt in the open position indefinitely there is a setting in LockView called Passage Mode Passage Mode can be assigned to an eLock...

Страница 9: ...tton to highlight CREDENTIAL MENU and press NEXT SELECT 4 Highlight DELETE CREDENTIAL and press NEXT SELECT 5 Credential to Delete will be displayed All of the occupied slots along with the name if on...

Страница 10: ...ECT to edit highlighted credential 8 Press to change Level Supervisor User press UP DOWN to highlight 2nd PIN To add a new or change an existing 2nd PIN enter a 4 14 digit number using the numeric key...

Страница 11: ...ed 1 Press MENU LOGIN PLEASE will be displayed 2 Scan valid credential or enter 4 14 digit PIN and press ENTER 3 Press DOWN button to highlight LCD BACKLIGHT and press NEXT SELECT 4 LCD Backlight will...

Страница 12: ...eal time clock q Time based access restrictions q Create user groups q WindowsTM based q Set up Escalating Notification System q View Compliance Dashboard q Dual Latch access available second latch re...