200/300 Series
— CompX cabinet eLock Instructions
6
Unit Features:
w
Choose 802.11g or Ethernet Networked configurations that
uses the facilities existing infrastructure for actual 2-way
read/write communication
w
Each eLock can hold any combination of up to 3,000
Supervisors and Users
w
Choose a model to use existing HID Prox, HID iCLASS, or
magstripe card credentials that can be programmed to
operate each eLock
w
Remote Notification System with programmable escalating
alerts via SMTP email; SMS text, voice and fax (Networked
eLock & LockView Software required)
w
Spring bolt latching mechanism provides automatic
relocking
w
Optional second latch drive output (requires additional
hardware)
w
Door position switch input (requires additional hardware)
w
Membrane keypads with stainless steel domes provides
durable performance and easy cleaning
What’s in the box?
w
1 – eLock controller
w
1 – motorized latch w/latch cable
w
1 – battery compartment
w
1 – battery cable
w
2 –
#
10 x ½" philips pan head hi-low blunt point (type B)
SEMS mounting screw (used to mount eLock controller on
sheet metal application)
w
2 –
#
10 x 1
7
/
32
" philips pan head hi-low blunt point (type B)
SEMS mounting screw (used to mount eLock controller on
MINIMUM
5
/
8
" thick application)
w
2 –
#
8 x
5
/
8
" philips pan head wood screw for mounting battery
compartment
w
4 –
#
10 x 1½" philips pan head wood screw for mounting
motorized latch
w
1 – warranty card
w
1 – serial code sticker set
w
1 – in-box instructions
What’s needed?
w
6 – AA alkaline batteries
w
Drill
w
#
2 philips head bit
w
½" drill bit for through hole battery cable
w
3
/
8
" drill bit for through hole Wi-Fi antenna cable
(300 Series Wi-Fi only)
w
7
/
32
" drill bit for through holes to mount eLock display unit
w
T15 pin-in Torx (6-lobe) bit or driver
Care and Cleaning
The eLock is a battery operated device, therefore, it should
be part of a regular battery maintenance program.
Warning: install the batteries as shown in the battery
compartment. Polarity (+) or (-) must be correct. Replace
batteries as a set. Always use new batteries when replacing
the old set. Do not combine a used battery with a new one.
Only use alkaline batteries; do not mix battery types.
To clean the surface of the eLock, apply non-acid based
cleaner to a clean cotton cloth; do not spray cleaner directly
on the eLock. Wipe down keypad and housing taking care
around the beeper opening and edges of keypads. Wipe
excess cleaner off of all surfaces.
Setting up the eLock
Getting Started Out of the Box
If the eLock is stand-alone 200 Series (direct connection
via USB to LockView Software v4) and will be used in
conjunction with CompX’s LockView Software v4, please
follow the
LockView Mode Instructions
below.
For Networked (802.11g or Ethernet) 300 Series eLocks,
please follow the
CompX eLock Database & Network
Configuration & Install Manual
and the
CompX LockView
Software Instruction Manual
before proceeding.
The eLock is shipped in
FACTORY
mode.
CONNECTING THE COMPONENTS
:
1. Attach one end of the battery cable to the connector on the
back of the eLock controller.
2. Attach the other end of the cable to the battery
compartment.
3. Attach latch cable terminal to Latch 1 connector. (See
diagram for connector locations.)
4. Install 6 AA alkaline batteries. (not included)
200/300 Series