background image

Timpdon Marine

 

Tel    0161 - 980 8054 

Issue 1 – May 2011

 

Web

 

www.timpdon.co.uk

  

 

EMail  [email protected]  

You are now in 

Step 2 – Servo Set Position 

 

The 

LED

 will flash with 

double short

 flashes, and the servo will move to 

the current 

set

 position. 

 
 

Adjust the required 

set

 position using either 

S1

 to increase the servo 

position or 

S2

 to decrease it. The actual rotation direction is servo 

dependent. 

 
 

When satisfied, press and hold both switches 

S1

 and 

S2

 together. 

 

The 

LED

 will flash rapidly for about 2 seconds, and then go on 

continuously. Then release both switches. 

 

 

If you release either switch before the LED stops flashing, the unit 
will remain in program Step 2. 

 

 

The unit will then proceed automatically to program 

Step 3 

 

 

You are now in 

Step 3 – Servo Rotation Rate 

 

The 

LED

 will flash with 

single long

 flashes, and the servo will rotate 

continuously between the current 

set

 and 

reset

 positions at the current 

rotation rate

 

There are sixteen separate 

rotation rates

, between 0.25 and 20 seconds 

for 90° rotation. Select the required 

rotation rate

 using either 

S1

 to 

increase the rate or 

S2

 to decrease it. After the last step, the rate will 

revert to the other end of the scale. 

 

 

When satisfied, press and hold both switches 

S1

 and 

S2

 together. 

 

The 

LED

 will flash rapidly for about 2 seconds, and then go on 

continuously.  Then release both switches. 

 

If you release either switch before the LED stops flashing, the unit 

will remain in program Step 3. 

 

 

The unit will then save all programmed values to non-volatile memory. 

 
 

The 

LED

 will then flash rapidly for about 4 seconds to indicate completion 

of programming, and then the 

MRSS2

 will automatically reboot in normal 

operation mode, with the new programmed settings operational. 

 
 

The 

MRSS2

 is now ready for use. 

Отзывы: