Timpdon Marine
Tel 0161 - 980 8054
Issue 1 – May 2011
Web
www.timpdon.co.uk
EMail [email protected]
2
You are now in
Step 2 – Servo Set Position
The
LED
will flash with
double short
flashes, and the servo will move to
the current
set
position.
Adjust the required
set
position using either
S1
to increase the servo
position or
S2
to decrease it. The actual rotation direction is servo
dependent.
When satisfied, press and hold both switches
S1
and
S2
together.
The
LED
will flash rapidly for about 2 seconds, and then go on
continuously. Then release both switches.
If you release either switch before the LED stops flashing, the unit
will remain in program Step 2.
The unit will then proceed automatically to program
Step 3
3
You are now in
Step 3 – Servo Rotation Rate
The
LED
will flash with
single long
flashes, and the servo will rotate
continuously between the current
set
and
reset
positions at the current
rotation rate
.
There are sixteen separate
rotation rates
, between 0.25 and 20 seconds
for 90° rotation. Select the required
rotation rate
using either
S1
to
increase the rate or
S2
to decrease it. After the last step, the rate will
revert to the other end of the scale.
When satisfied, press and hold both switches
S1
and
S2
together.
The
LED
will flash rapidly for about 2 seconds, and then go on
continuously. Then release both switches.
If you release either switch before the LED stops flashing, the unit
will remain in program Step 3.
The unit will then save all programmed values to non-volatile memory.
The
LED
will then flash rapidly for about 4 seconds to indicate completion
of programming, and then the
MRSS2
will automatically reboot in normal
operation mode, with the new programmed settings operational.
The
MRSS2
is now ready for use.