13.03.2019 | V1.81
6 | 9
Overfill Prevention Controller EUS-2 |
Technical Description
[email protected]
www.timm-technology.de
5.
Technical Specifications
5.1.
Operating Data
Device category according to ATEX
(directive 2014/34/EU)
II 2 [1] G
Type of protection
Ex eb ib q [ia Ga] IIB T4 Gb
Protection of enclosure
IP66
Shut down response time
≤ 450 ms
Power Supply
Type of protection ‘increased safety’
Ex eb
230 V AC ± 10 %, 50-60 Hz,
about. 25 VA
Ambient temperature range
-40 °C to +60 °C
Dimensions
475 mm, 215 mm, 120 mm (H, W, D)
Weight
about 10 kg
5.2.
Sensor and Grounding Circuits
Type of Protection
“intrinsic safety” Ex ia
For connection to apposite level sen-
sors
Maximum 8 two-wire-sensors or
Maximum 12 five-wire-sensors
Cable length
Maximum 50 m (Ex specification,
functional limitations must be ob-
served)
Maximum values
Uo = 12,7 V, Io = 129 mA,
Po = 360 mW
5.3.
Control Output Circuits
Contact Outputs
Type of protection “Increased safety”
Ex eb
Maximum values: 250 V AC, 3 A, 100 VA
2 Filling release Contacts
redundant, potential-free, intern
monitored, closing contacts
2 Additional Contacts
Potential-free changeover contacts,
configurable for detailed signalling
‘grounding’, ‘overfilling’, ‘filling pro-
cess’, ‘parking position’
Electronic Output (E1, E2)
Type of protection “Intrinsic safety”
Ex ib
NAMUR-compatible
For connection to certified intrinsi-
cally safe circuits
Maximum values
Ui ≤ 15 V, Ii = 20 mA, Pi = 300 mW
Electronic Filling Release Output
potential-free, oscillating (fail-safe)
Additional Electronic Output
potential-free, optionally switchable
static or oscillating
Serial Data Interface
Type of protection: ‘Intrinsic Safety’
Ex ib
For connection to TExi-Bus (Timm
intrinsic safety databus)
Maximum values: Ui ≤ 15 V, Ii ≤ 175
mA, Pi ≤ 2,4 W