4.

 

Accessories  

TIMM provides a variety of accessories for 
its Overfill Prevention Controller. 

4.1.

 

Coiled Cable  

The  coiled  cables  come  in  two  lengths, 
with  truck  connector  plugs  according  to 
EN 13922 or API RP 1004 as well as with or 
without disconnector plug. 

 

EUS-1-SK7:

  blue  PUR  coiled  cable 

with  truck  connector  plug,  cable 
length about 2.6 m, expandable to 
about  7.5  m  for  direct  connection 
to the control unit. 

 

EUS-1-SSK7:

  as  type  above-men-

tioned, but with additional discon-
nector  plug  for  detachable  con-
nection  to  disconnector  socket 
junction  box  EUS-1-ST  or  EUS-1-
STP. 

 

EUS-1-SSK3:

  as  type  above-men-

tioned, but in short length of about 
1.5  m,  expandable  to  about  3.5  m; 
particularly  intended  for  use  with 
disconnector  socket  junction  box 
type  EUS-1-STG11/11P  at  loading 
arm  

Available truck connector plugs mounted 
to the coiled cables:

 

 

Black 10-pole

 plug with 

four lock-

ing  pins

  and 

ten  electrical  con-

tacts

,  according  to  EN 13922  (for 

thermistor type and optic type ve-
hicle sensor systems). 

 

Blue

 marked plug with 

three lock-

ing pins

 and 

seven electrical con-

tacts 

(fitting onto 6-pin truck sock-

ets for optic vehicle sensor systems 
acc. to API RP 1004 standard). The 
additional  7th  pin  is  intended  for 
identifying the parking socket. 

Electrical contacts of the plug are used as 
well  for  detecting  the  park  position  in 
combination  with  suitable  parking  sock-
ets. 

 

 

 

 

 

 

 

4.2.

 

Disconnector Socket  

The  following  intrinsically  safe  discon-
nector socket junction boxes are available:  

For installation at 

filling gantry

 

EUS-1-ST: 

junction  box  with  dis-

connector  socket  to  connect  a 
plug-in  coiled  cable  type  EUS-1-
SSK7 or EUS-1-SSK3; complete with 
1 m uncoiled cable for connection 
to the control unit.

 

 

EUS-1-STP: 

as  type  above-men-

tioned,  but  with  additional  code-
generating  truck  socket  for  de-
tecting  the  ‘truck  connector  in 
park position’ status.

 

 

EUS-1-ST2P2: 

dual  junction  box 

with two disconnector sockets for 
the detachable connection of two 
coiled  cables  with  different  truck 
connector  plugs  to  the  controller; 
including  two  park  position  sock-
ets. 

 

 

 

 

 

 

 

Truck connector 
plug 

Disconnector 
plug 

Figure 4: Coiled cable with disconnector plug

 

Disconnector plug 
fort ruck connector 
plug 

Disconnector socket 
with bolt handles for 
truck cables with dis-
connector plug 

Figure 5: Disconnector socket junction box  

EUS-1-STP 

Содержание EUS-2

Страница 1: ...H Timm Elektronik GmbH Humboldtstr 29 21509 Glinde GERMANY OVERFILL PREVENTION CONTROLLER EUS 2 Technical Description Version 1 81 English...

Страница 2: ...n Protection 2 3 3 High Functional Safety Fail Behavior 2 3 4 Bright Signal Light 2 3 5 Graphic Display 2 3 6 Easy Configuration by Joystick 3 3 7 Reliable Ground Verification 3 3 8 Control Outputs Da...

Страница 3: ...nnection The level sensors are positioned in the top of each tank compartment deep enough to as sure that once a sensor gets activated product flow stops before the compart ment is completely full In...

Страница 4: ...With this unique combination of the types of protection the main housing can be opened in gas hazardous areas when power is switched on for configuration and service e g for setting the additional co...

Страница 5: ...e plug and socket connection will be noticed in time for pre ventive measures 3 8 Control Outputs Data Interface Six control outputs enable advanced op tions for connecting the control unit ac cording...

Страница 6: ...systems Blue marked plug with three lock ing pins and seven electrical con tacts fitting onto 6 pin truck sock ets for optic vehicle sensor systems acc to API RP 1004 standard The additional 7th pin...

Страница 7: ...onal truck socket for detecting the truck connector in park position status by integrated socket code generator 4 3 Testing Equipment The functioning of the control unit can easily get checked by usin...

Страница 8: ...functional limitations must be ob served Maximum values Uo 12 7 V Io 129 mA Po 360 mW 5 3 Control Output Circuits Contact Outputs Type of protection Increased safety Ex eb Maximum values 250 V AC 3 A...

Страница 9: ...ower supply 1 2 Closing contact output K1 Filling release 3 4 Closing contact output K2 Filling release 5 7 Switching contact output K3 Configurable 8 10 Switching contact output K4 Configurable 15 16...

Страница 10: ...s In addition to the ATEX certificate we also have Ex approvals for the EUS 2 according to IECEx and EAC Ex according to TR CU 012 2011 for Australia Oceania and the Eurasian cus toms union Europe EU...

Страница 11: ...es or technical support our employees will be glad to be available for you on the following contact information Dr Alexander Zelck Head of international sales 49 40 248 35 63 31 zelck timm technology...