Proximity switch adjustment
Warnings
1) Identifiy the position along the actuator where the limit
switch must work, there the sensor dog must be fixed.
2) Insert the fixing nuts in the profile slot accessing through
the upper plate. Repeat the operation also for the sensor
dog to be installed in the lower side of the profile (Fig.26).
3) Fasten the sensor dog in place (Fig.27).
4) Insert the proximity switch on the carriage plate, and
tighten it until it gets in contact with the sensor dog.
Then losen it for 1/2 turn to bring it to the correct
distance (Fig. 28).
5) Tighten the proximity switch in position by tightening the
lock nut (Fig. 28).
WARNING
: the safety block must NEVER be used as an ope-
rational end stop of the stroke.