background image

2

TEMPERATURE RANGE

1. Recommended for use within the temperature range of 14º F to 122º F (-10º C to 50º C).
2. Prolonged temperatures exceeding 122º F (50º C) may diminish the stability of the plastic cartridge and result in a reduction

of pressurization.

3. Prolonged operation below 14º F (-10º C) may cause a reduction in performance and battery life.

STORAGE CONDITIONS

1. Store M-Power units and lube cartridge kits in a dry location. Recommended storage: 68º F (20º C).

SHELF LIFE

1. Lube cartridge (filled): One year depending on lubricant
2. Drive (without batteries): Unlimited
3. Batteries: One year

ENCLOSURE RATING AND CERTIFICATION

1. NEMA 13 / IP 54. Protected against dust and splash water.
2. UL and CE Certified

DISPOSAL

1. Empty lubricant cartridge: dispose with standard grease waste.
2. Batteries: dispose at local waste disposal (battery collection) points.
3. Drive units: not applicable. M-Power units are reusable for several applications.

WARRANTY

1. Lubricant cartridge: 1 year (Also dependent on lubricant manufacturer’s warranty for life of lubricant.)
2. Drive: 1 year

Note 1:

1 cc = approx. 1 “shot” of grease from a typical grease gun

Note 2:

The drive motor is controlled by a circuit-board timer. It cycles on a given schedule to expel a small amount of 

lubricant. Cycle times are listed on the previous page.

M-Power 300 Installation Instructions – Lube Cartridge Kit

THE LUBE CARTRIDGE KIT

1. Timken supplies a replacement lubricant cartridge to service empty M-Power lubricators. The lubricant cartridge comes

with a battery pack. This package is referred to as the “Lube Cartridge Kit.”

SERVICING AN EMPTY MOTORIZED LUBRICATOR

1. M-Power comes with a reusable drive motor.
2. M-Power has LED performance lights that indicate – among other things – when the lubricant cartridge is empty.
3. A green-red flashing signal indicates an empty lubricant cartridge.
4. The lubricant cartridge is a one-time-use reservoir. Empty lubricant cartridges should be discarded (with standard grease

waste) and replaced with new, factory-filled lubricant cartridges.

Note:

Lubricant cartridges cannot be refilled. Attempts to refill these units in the field will void the manufacturer’s warranty.

REPLACING AN EMPTY LUBE CARTRIDGE WITH A FULL LUBE CARTRIDGE

Отзывы: