5. Operation in AUTO & PHOTOCELL Mode

Move the slide switch to the AUTO & PHOTOCELL position and turn the rocker switch ON. In 

this mode the unit will turn ON at dusk and OFF at a time programmed by the user. To do this it 

needs an ON time prior to dusk to be programmed by the user along with the above OFF time 

(see Programming Instructions). A safe ON time to cover the whole year anywhere in the U.K. is 

1400 hours. A additional ON period can be programmed for the early morning if required. This 

will only operate if the ON time occurs in darkness and will last until the programmed OFF time. 

In this mode the rocker switch can be used manually to turn the lamp OFF once a programmed 

ON period has started, but not to turn it ON during a programmed OFF period.

Override button (also 

used in conjunction with 

programme button to 

set the clock and ON/

OFF times/days)

Day 

marker

24 hour 

display

Guarded tamper resistant 

programme button used to 

select the clock time and the 6 

“ON/OFF” times/days and to 

review them once set

6  Battery

This product has a factory fitted rechargeable battery. If the unit is left with its mains power 

switched off for more than 1 month the display may go blank. In this case switch mains on, 

wait four hours, and apply reset – see 9 before programming.

7.  Programming Overview

This is a seven day (weekly) timeswitch which has six programmes, each of which can be block 

programmed to work on all of the five weekdays, both weekend days, or all 7 days (24 hour 

operation). Programmes can also be designated to operate on individual days. 

ZV700 – Programming Instructions

Содержание ZV700

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 7 Day Digital Lightswitch with Optional Dusk Start Cat No ZV700...

Страница 2: ...timed control of lighting on a weekly basis available at the slide of a switch There is a further option of starting an automatic lighting period at dusk but ending it in the usual way with a timed O...

Страница 3: ...mme memory and the second is the ability to switch low energy fluorescent and low voltage lighting Override button also used in conjunction with the programme button to set the clock and ON OFF times...

Страница 4: ...rminal the remaining two wires connect to terminals L1 and L2 in either position If two wires are connected to any one terminal on the original switch these should be kept together and inserted into t...

Страница 5: ...Reset button with a pen or matchstick until the display disappears and then clears to show 0 00 system reset If the rocker switch is turned to the ON position and the Change button is pressed the ON s...

Страница 6: ...iod has started but not to turn it ON during a programmed OFF period Override button also used in conjunction with programme button to set the clock and ON OFF times days Day marker 24 hour display Gu...

Страница 7: ...utes are flashing they may be set using the Change button Once set the Program button is pressed again to proceed to the next stage Programming can be carried out with the slide switch in any position...

Страница 8: ...y ii Hour Setting Press the Program button briefly to select the hours display shows clock symbol and the hours digits flashing Press the Change button to advance the hour setting For rapid hours sele...

Страница 9: ...weekdays If another option is required the change button should be pressed until the correct day s flash ii Once the day option has been selected press Program button briefly to select hour time disp...

Страница 10: ...ating Programme Mode This is required when making changes to the clock time day or programme times days and can be initiated any time during the normal operating mode Press the Program button briefly...

Страница 11: ...dswhilstinnormaloperatingmodeasmall Rappearsonthedisplay TheunitwillnowswitchONandOFFinarandomfashionduring programmedONperiodsinbothAUTOandAUTO PHOTOCELLmodes BoththeONandtheOFF periodswillvaryinaran...

Страница 12: ...e timeguard com HELPLINE 020 8450 0515 For assistance with the product please contact 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture wi...

Отзывы: