background image

13

14

3 Year Guarantee

In the unlikely event of this product becoming faulty due to defective 
material or manufacture within 3 years of the date of purchase, 
please return it to your supplier in the first year with proof of 
purchase and it will be replaced free of charge. For the second  
and third years or any difficulty in the first year telephone the  
helpline on 020 8450 0515.
Note: A proof of purchase is required in all cases. For all eligible 
replacements (where agreed by Timeguard) the customer is 
responsible for all shipping/postage charges outside of the UK.  
All shipping costs are to be paid in advance before a replacement  
is sent out.

Содержание Weathersafe Extreme WXT103N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Weathersafe Extreme...

Страница 2: ...nt IEE wiring and Building Regulations IP66 Products covered by these instructions WXT201N Twin Gang Socket Switched 13A WXT104NP Single Gang RCD Fused Spur 13A WXT204NP Twin Gang RCD Socket Switched...

Страница 3: ...the appliance To clean use a clean dry cloth only Do NOT use any liquid cleaners During use warming of the enclosure is normal Wiring tests Important WXT104NP WXT204NP WXT205NP Remove this product fr...

Страница 4: ...uitable for 2 and 3 wire applications Breaking capacity 250A Earth leakage Through fault withstand 1500A Trip Speed Less than 40msec at 150mA residual current Classification WXT104NP Latching Passive...

Страница 5: ...ed screws Lid clip for padlocks 4 WXT101N WXT201N WXT103N Installation 1 IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before...

Страница 6: ...k plate If the mounting position desired is uneven use a sheet of marine ply as a base plate and fit the back box Insert the rawl plugs into the holes 4 Drill the wall using a 4mm drill bit making sur...

Страница 7: ...e screws for the rawl plugs installed Ensure that the back box is correctly orientated following the TOP marking which is labelled inside 9 Pass though the 230V AC 50Hz mains supply cable and secure t...

Страница 8: ...7 Figure 4 WXT101N Figure 5 WXT201N 230V 50Hz AC Mains Supply Earth Mains Neutral Supply 230V 50Hz AC Mains Supply Earth Mains Neutral Supply 4 1 WXT101N WXT201N WXT103N Wiring Diagrams...

Страница 9: ...8 Figure 6 WXT103N 230V 50Hz AC Mains Supply Earth Earth Mains Neutral Supply Live Supply Out Neutral Supply Out...

Страница 10: ...r switching off the circuit breaker before proceeding with the installation 2 Using a Philips screwdriver separate the faceplate from the back box by removing the four tapped screws located in each co...

Страница 11: ...drill bit making sure not to infringe or compromise any gas water pipes or cables Insert the rawl plugs into the holes 5 The drain feature must be drilled out using a 5mm drill if the top or side entr...

Страница 12: ...y is observed see figure 9 and 10 for the appropriate wiring diagram for your chosen product Note that if metal conduit is being used the earth continuity between the conduits must be maintained 10 On...

Страница 13: ...SET press the grey blue for WXT205NP button marked reset R again the status indicator should show red If all the above operations work satisfactory the RCD is safe for use If this test procedure is no...

Страница 14: ...purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all...

Страница 15: ...14...

Страница 16: ...csc timeguard com For a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return...

Отзывы: