background image

3

4. Siting

• The TRT036N should be located at a position which eases wiring runs  

and gives good access for programming.

• It should be mounted approximately 1.5m above floor level. 

5. Installation 

5.1 Ensure the mains supply is switched off and the circuit supply fuses  

are removed or the circuit breaker turned off.

5.2 Remove the wall plate from the unit, by undoing the retaining screws, 

and pivoting the bottom of the unit outwards. The TRT036N body can 
then be lifted off.

5.3 Mark the position of the mounting holes on the wall using the wall plate 

as a template. Drill out the mounting holes taking care to avoid any 
joists, electrical cables or water/gas pipes that may be hidden beneath 
the surface. Insert the rawl plugs into the holes.

5.4 Pass the 230V 50Hz mains supply and load cables through the opening 

of the wall plate. Allow sufficient excess cable to wire up the unit, but 
not too much to make it difficult to close the unit to the wall plate.

5.5 Fix the wall plate to the wall using the correct mounting screws for the 

rawl plugs installed. The retaining screws which secure the unit to the 
wall plate should be at the bottom.

5.6 Terminate the cables into the terminal block ensuring correct polarity 

is observed and that all bare conductors are sleeved (See section 6. 
Connection Diagram). Make sure that the curved washer grips 
the conductor.

5.7 To reinstall the unit onto the wall plate, first ensure the wall plate 

retaining screws are loosened enough to clear the TRT036N body, 
then engage the top of the TRT036N onto the wall plate retaining tabs, 
and push firmly downwards and then upwards. There will be some 
resistance from the terminals.

5.8 Once in place, secure with the retaining screws making sure 

not to over tighten.

Содержание TRT036N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 7 Day Digital Programmer 2 Channel Surface Mount Model TRT036N...

Страница 2: ...cuit breaker To clean use a clean dry cloth only Do not use any liquid cleaners 3 Technical Specifications 230V AC 50 Hz This thermostat is of Class ll Construction and must not be earthed Switch Rati...

Страница 3: ...am pm or 24hr clock timer display illuminated on setting The heating symbol will show when heat is demanded for both channels Flip down cover conceals setting buttons Advance to next Programme ON OFF...

Страница 4: ...pply and load cables through the opening of the wall plate Allow sufficient excess cable to wire up the unit but not too much to make it difficult to close the unit to the wall plate 5 5 Fix the wall...

Страница 5: ...4 TRT036N Wall Plate Alternate mounting holes Wall plate retaining screws Retaining tabs Mounting holes Loop terminal...

Страница 6: ...nection Diagram Connect the 230V 50Hz mains supply and load cables to the terminal block which are marked as follows Note Check boiler instructions before connecting 230V 50Hz Mains Supply Live Supply...

Страница 7: ...he DIP switch positions You can set the TRT036N to run a Pumped or Gravity system It is important to check which system you have before setting the DIP switches and operation This can also be set usin...

Страница 8: ...ollowed by the 12hr clock format screen After 1 minute the screen will time out showing a default time of 12 00AM There are 3 timed controlled periods per day and the default Programmes are as follows...

Страница 9: ...rm 9 6 The year will flash use the Up Down arrow buttons to alter the year and press the Select button once to confirm 12Hr AM PM format Use the Up Down arrow buttons to change the time format 24Hr fo...

Страница 10: ...onfirm and exit Use the Up Down arrow buttons to change the month The month will flash Use the Select button to confirm Use the Up Down arrow buttons to change the day The day will flash Use the Selec...

Страница 11: ...tailed further in the instructions read the instructions in full before you begin The following steps use the individual 7 day Programming as an example The steps for weekday weekend 5 2 Programming a...

Страница 12: ...the minutes and press the Select button once to confirm 10 8 The P2 ON Programme 2 ON hour will flash Follow steps 10 3 to 10 6 for P2 Programme 2 ON and OFF and also P3 Programme 3 ON and OFF 10 9 Pr...

Страница 13: ...ill need to be Programmed unwanted times need to be entered as the same time i e P2 ON 7 00AM P2 OFF 7 00AM P3 ON 7 00AM P3 OFF 7 00AM Unwanted days of the week need to be entered as the same time i e...

Страница 14: ...step 10 15 until you have copied the programme to all of the days of the week that are required 10 17 Press the Set button twice to exit the programme entry Copy and the day of the week will flash Us...

Страница 15: ...next OFF ON until next programmed OFF Note If no button is pressed it will time out after 60 seconds and return to the mains screen showing day time and output status The display light will also time...

Страница 16: ...imed period to 2 hours a third press for 3 hours and a fourth press for 0 hours which will cancel the boost timed period and return you to normal operation The boost setting will time out after 15 sec...

Страница 17: ...ton once to confirm and exit or confirm and exit by leaving the screen to time out after 15 seconds Any key press will illuminate the screen also with a 15 second time out after the last button press...

Страница 18: ...be displayed in the top right had corner of the screen To cancel the holiday press the Display light Holiday button and hold for 3 seconds The holiday duration and suitcase symbol will disappear Holi...

Страница 19: ...purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all...

Страница 20: ...l csc timeguard com For a product brochure please contact HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com Qualified Customer Support Co ordinators will be on line to assist in...

Отзывы: