background image

3

4

4. Siting

•  The TRT030N must be sited where it will not be influenced  

by heat sources, for example above a radiator or a television or  
a refrigerator/freezer or in direct sunlight or subjected to draughts.

•  The product requires air circulation, so do not position above  

or below shelving or other wall mounted obstacles. 

•  It should be mounted approximately 1.5 metres above floor level.

5. Installation 

5.1  Ensure the mains supply is switched off and the circuit supply fuses  

are removed or the circuit breaker turned off.

5.2  Remove the wall plate from the unit, by undoing the retaining screws, 

and pivoting the bottom of the unit outwards. The TRT030N body  
can then be lifted off.

5.3  Mark the position of the mounting holes on the wall using the wall plate 

as a template. Drill out the mounting holes taking care to avoid any 
joists, electrical cables or water/gas pipes that may be hidden beneath 
the surface. Insert the rawl plugs into the holes.

5.4  Pass the 230V 50Hz mains supply and load cables through the opening 

of the wall plate. Allow sufficient excess cable to wire up the unit, but 
not too much to make it difficult to close the unit to the wall plate.

5.5  Fix the wall plate to the wall using the correct mounting screws for the 

rawl plugs installed. The retaining screws which secure the unit to the 
wall plate should be at the bottom.

5.6  Carefully remove the plastic terminal cover. Terminate the cables into 

the terminal block ensuring correct polarity is observed and that all bare 
conductors are sleeved (See section 6. Connection Diagram).  
Make sure that the curved washer grips the conductor.  
Reposition the plastic terminal cover and push into place.

Содержание TRT030N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Electronic Room Thermostat Model TRT030N...

Страница 2: ...otal load on the circuit including when this thermostat is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean use a clean dry cloth only Do not use any liquid clea...

Страница 3: ...ustment 3CYC Gas 6CYC Oil set by DIP switch Output Light Blue LED CE Compliant Dimensions H x W x D 86 x 88mm x 38mm TRT030N Front View Set temperature adjustment scale Blue LED output indicator Easy...

Страница 4: ...l using the wall plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into...

Страница 5: ...ll plate retaining screws are loosened enough to clear the TRT030N body then engage the top of the TRT030N onto the wall plate retaining tabs and push firmly downwards and then upwards There will be s...

Страница 6: ...ns Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N A Loop Terminal is provided should a 3 core cable be used Load Boiler Switch Live Brown or Red to NO 6 Connection Diagram Conn...

Страница 7: ...ll intermittently turn the heating ON and OFF to help prevent temperature over shoot The boiler type can be set to either 3CYC Gas or 6CYC Oil using the DIP switches on the rear of the unit 8 Operatio...

Страница 8: ...rd Customer Helpline 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your sup...

Отзывы: