background image

1

1. General Information

These instructions should be read carefully and retained for further reference 
and maintenance.

2. Safety

•  Before installation or maintenance, ensure the mains supply to the 

thermostat is switched off and the circuit supply fuses are removed or the 
circuit breaker turned off.

•  It is recommended that a qualified electrician is consulted or used for the 

installation of this thermostat and install in accordance with the current 
IEE wiring and Building Regulations.

•  Check that the total load on the circuit including when this thermostat is 

fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.

•  To clean use a clean dry cloth only. Do not use any liquid cleaners.

3. Technical Specifications

•  230V AC 50 Hz
•  This time switch is of Class ll Construction and must not be earthed
•  Switch Rating: 

6(2)A

•  Switch Type: 

Single pole, single throw (SPST)

•  Connection Type: 

3 wire

•  Installation Type: 

Surface mount with wall plate

•  Micro Disconnection: 

Type 1.B control action

•  Operating Temperature Range:  0°C to +40°C
•  Set Temperature Range: 

M5°C (frost setting)  

 

to m30°C

•  Temperature Swing Adjuster:  +/- 0.5°C or 1.0°C set by DIP switch
•  PID Adjustment: 

ON or OFF set by DIP switch

Содержание TRT030N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Electronic Room Thermostat Model TRT030N...

Страница 2: ...otal load on the circuit including when this thermostat is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean use a clean dry cloth only Do not use any liquid clea...

Страница 3: ...ustment 3CYC Gas 6CYC Oil set by DIP switch Output Light Blue LED CE Compliant Dimensions H x W x D 86 x 88mm x 38mm TRT030N Front View Set temperature adjustment scale Blue LED output indicator Easy...

Страница 4: ...l using the wall plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into...

Страница 5: ...ll plate retaining screws are loosened enough to clear the TRT030N body then engage the top of the TRT030N onto the wall plate retaining tabs and push firmly downwards and then upwards There will be s...

Страница 6: ...ns Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N A Loop Terminal is provided should a 3 core cable be used Load Boiler Switch Live Brown or Red to NO 6 Connection Diagram Conn...

Страница 7: ...ll intermittently turn the heating ON and OFF to help prevent temperature over shoot The boiler type can be set to either 3CYC Gas or 6CYC Oil using the DIP switches on the rear of the unit 8 Operatio...

Страница 8: ...rd Customer Helpline 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your sup...

Отзывы: