P A S S I V E   I N F R A - R E D

M U L T I   S E N S O R

S W I T C H   &

D E T E C T O R

Cat No. SL055

7

8

10

9

INST

ALLA

TION & OPERA

TING

INSTRUCTIONS

HELPLINE

020-8450-0515

For a product brochure please contact:

Timeguard Ltd.

Victory Park, 400 Edgware Road,

London NW2 6ND

Tel: 020-8452-1112

or email [email protected]

Designed and manufactured in the U.K. 67-057-45 [2]

Specifications

Supply voltage

220 –240V 50Hz

Power consumption

6VA Lamps off

Lighting load

Incandescent /tungsten halogen
3000W Maximum (1500W each zone)

SUITABLE FOR FLUORESCENT LIGHTING AND LOW ENERGY BULBS
UP TO 500W MAXIMUM IN EACH ZONE
Light-on-time

Adjustable from 5 seconds to 5 minutes. 
Timing interval starts from last detection.

Light level

Adjustable from 5 lux to 100 lux using zone 
1 detector.

Detection coverage

2 independent zones of detection with up to 4 Wall 
Sensor Detectors (SL099) each zone. Detector range 
up to 15 metres at an ambient temperature of 20°C 
and 180° coverage in the horizontal plane.

Protection rating

Wall Sensor Detector (SLO99) – IP54

Operating rating

-20°C to +50°C

Conforms to directives: 73/23/EEC and 89/336/EEC

5 Year Guarantee

We shall repair or at our option replace this product if it becomes defective
within 5 years of the date of purchase, provided that you return it to us with
proof of purchase. A product becomes defective where it fails due to fault in
the material or workmanship, but not where the failure is caused by an
accident, misuse or neglect. This guarantee does not effect your rights under
statute or common law.

Points to Remember

• Installation should be carried out by a competent DIY person. If in doubt

consult a qualified electrician.

• The electricity supply must be disconnected whist carrying out the

installation.

• An earth connection must be made for safety.
• The Multi Sensor Switch is for internal siting only. Wall Sensor Detectors

are mounted externally.

• Use the 2 strips of insulating sleeve (supplied) to insulate the 2 core low

voltage cable run inside the Multi Sensor Switch.

• Wall Sensor Detectors should be mounted at a height of 2.5 metres. At this

height the detector can be adjusted within minimum and maximum
settings. Refer to adjust detection range setting.

• Set light level/time on controls as shown under section heading.
• In normal use a built-in light sensor prevents daylight operation unless

light adjuster is set to day and night operation.

• False alarms may occur (see siting).
• The Sensor detector is more sensitive to movement across the detector

rather than directly towards or away from it.

• To help distinguish in what zone an intrusion has occurred: 

ZONE 1 buzzer sounds a continuous bleep – bleeeeeep ZONE 2 buzzer
sounds a fast Intermittent bleep –bleepbleepbleepbleep

Installing the Wall Sensor Detector

A maximum of 8 detectors – 4 each zone can be installed using low voltage 2
core cable (bell wire).

Siting

The Wall Sensor Detector should be mounted
at a height of 2.5 metres. At this height the
sensor can be adjusted within minimum and
maximum settings.  Refer to adjusting
detection range.
Maximum sensitivity is achieved when
movement of people is past the detector rather than movement directly
towards or away from it.

False Alarms

It may also respond to cars, anumals, central heating flues, cold moving objects
against a warmer background (e.g. swaying trees in front of a warm wall).

Fixing Sensor Detector 

to the Wall

i.  Unscrew and pull off front cover
ii.  Mark fixing holes A & B and drill holes
iii.  Fix unit to the wall using 2 x No 8 1 

1

2

"

(40mm) screws and wallplugs (not
supplied)

iv.  Replace front cover on completion 

of Wiring and walk testing.

Adjusting Detection Range

i.  Unscrew and pull off front cover
ii.  Loosen field adjustment screw
iii.  Using terminal block slide up or down into position Up=Minimum setting

at 2.5 metres 180° Down=Maximum setting at 15 metres 180° (Refer to
detection range).

iv. Once the range is established lock the terminal block into position by

tightening the field adjustment screw.

v. Replace front cover and secure with cover screw.

Wiring

All Wall Sensor Detectors should be wired in parallel back to the Multi Sensor
Switch terminals zone 1 and 2 (refer to Multi Sensor Switch cable plan). 
A low voltage 2 core cable (bell wire) should be used. For convenience wiring
may be looped from one detector to the next. Alternatively a junction box may
be used.

Detection Range

Walk Testing

Before commencing the walk test turn the Light level adjuster on the Multi
Sensor Switch to       the day and night setting and both zone 1 and 2 light 
on time adjusters to      the minimum light on time setting.
Switch on the mains electricity supply to the Multi Sensor Switch and wait 20
seconds for the switch to stablilise.
Starting at a distance greater than 15 meters from the Wall Sensor Detector
walk across the front of the unit gradually
moving closer. Note the position where
detection occurs. The light will remain on for
approximately 3 seconds. Continue this
pattern to establish the full extent of coverage.
Reset the light level and light on time controls
on the controlling switch. Commissioning is
now complete.

2.5m

2.5m

Maximum detection area
Minimum detection area

2.5m

2.5m

15m

20m

3m

15m

180° PIR lens

Fixing holes
Cut out for 2 core

cable entry

Terminal block slides up and down to

adjust detection range

Up = minimum 

Down = maximum

Front cover

Front cover

screw

Knock out for 2 core cable entry

Field adjustment screw

Terminal block

The detection angle masking

area may be reduced by

masking the lens with

adhesive PVC tape cut to

required width.

From Multi

Sensor switch

Route 2 core cable through case cut out into terminal blocks and secure

(cable knockout on front cover)

To next Wall

Sensor detector

Terminal block

Low voltage 

2 core cable 

(Bell wire)

Masking the Detection Area

Содержание SL055

Страница 1: ...PA S S I V E I N F R A R E D M U LT I S E N S O R S W I T C H D E T E C T O R Cat No SL055 I N S T A L L A T I O N O P E R A T I N G I N S T R U C T I O N S S ...

Страница 2: ...m screws for earth termination see wiring section 2 x 40mm CHROME SCREWS to secure Multi Sensor Switch to wall box see installing switch section 2 x 165mm LONG PVC INSULATION SLEEVES to insulate low voltage 2 core cable inside switch see wiring section General Apassiveinfra redMultiSensorSwitchand180 sensor detector providingsecurity lightingcontrolineither1or2zones Thewallswitchisdesignedtobesite...

Страница 3: ...he day and night operation Turn adjuster arrow anti clockwise for a darker start operation NOTE Thereisonlyonelightleveladjustercontrollingbothzones Thewallsensor detectorconnectedtozone1withinthedarkestlitareasetsthelightlevel Audible Alarm Selector OFF Independent to each zone Internal buzzer alarm permanently OFF The internal buzzer alarm will sound for approx 1 second each time movement is det...

Страница 4: ...witch is for internal siting only and can be either flush mounted or surface mounted onto an interior wall Surface Mounted Wiring INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT DIY PERSON IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN THE MAINS SUPPLY TO THE UNIT SHOULD BE FUSED AT 3 AMPS Light loads up to 500W 13 AMPS Light loads between 500 1500W AND ALSO INCORPORATE AN ON OFF SWITCH It must be ...

Страница 5: ...g at 2 5 metres 180 Down Maximum setting at 15 metres 180 Refer to detection range iv Once the range is established lock the terminal block into position by tightening the field adjustment screw v Replace front cover and secure with cover screw Wiring All Wall Sensor Detectors should be wired in parallel back to the Multi Sensor Switch terminals zone 1 and 2 refer to Multi Sensor Switch cable plan...

Страница 6: ... Switch is for internal siting only Wall Sensor Detectors are mounted externally Use the 2 strips of insulating sleeve supplied to insulate the 2 core low voltage cable run inside the Multi Sensor Switch Wall Sensor Detectors should be mounted at a height of 2 5 metres At this height the detector can be adjusted within minimum and maximum settings Refer to adjust detection range setting Set light ...

Страница 7: ...INE 020 8450 0515 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com Designed and manufactured in the U K 67 057 45 2 ...

Отзывы: