Light ON Time Adjuster

Sets the length of time the light(s) remain on after detection by a Wall Sensor
Detector

Turn adjuster arrow anti-clockwise for minimum on time.

Turn adjuster arrow clockwise for a longer time on period.

Timing is adjustable from approx 5 seconds to 5 minutes.

Zone Link

Both zones can be linked via a removable selector link on the back of the
switch.

ZONE LINK OFF - Light on times operate independently of
each other.

ZONE LINK ON - Light on times are governed by the zone set
with the longest light on time period. All Wall Sensor Detectors
in either zone will operate the system with this link

Light Level Adjuster

The adjustable light level control (100 Lux – 5 Lux determines at what part of
the day the system operates when set in AUTO (PIR) operating mode

Turn adjuster arrow fully clockwise for the day and night
operation.

Turn adjuster arrow anti-clockwise for a darker start operation.

NOTE: There is only one light level adjuster controlling both zones. The wall sensor
detector connected to zone 1 within the darkest lit area sets the light level.

Audible Alarm Selector - OFF/

(Independent to each zone)

Internal buzzer alarm permanently OFF

The internal buzzer alarm will sound for approx. 
1 second each time movement is detected by a Wall
Sensor Detector. NOTE: This facility operates over a
24hr period and can function independently of the
operating mode selections  (OFF/AUTO/ON) above.

To help distinguish in what zone an intrusion has
occurred. ZONE 1 buzzer sounds a Continuous
bleep – bleeeeeep ZONE 2 buzzer sounds a fast
intermittent bleep –  bleepbleepbleepbleep

LED Indicator

(Independent to each zone)

OFF – LED does not show

AUTO – Led shows on detection of movement
detected by the Wall Sensor Detector. The indicator
will remain on for the same period as the light on
time selector. (see light on time adjuster.)

ON – LED remains permanently ON.

Multi Sensor Switch Controls

Each of the zone controls are independent of each other allowing individual
zone settings or combined operation. NOTE: There is only one light level
adjuster for both zones which is set in conjunction with the sensor detector
connected to zone 1 in the darkest lit area.

Operating Mode Selector OFF/Auto/ON

(Independent to each zone)

Light(s) permanently OFF

Light(s) operational in conjunction with PIR Wall
Sensor Detectors

Light(s) permanently ON

4

3

6

5

2

1

Operating mode

selector

ZONE 2 

CONTROLS

ZONE 1 
CONTROLS

Audible

alarm

selector

Audible

alarm

selector

40mm

Chrome

screw

40mm

Chrome

screw

LED

indicator

Light on time adjuster

40mm chrome screws

40mm chrome screws

Multi Sensor switch

Multi Sensor switch

Use a Std. 2 gang 25mm deep metal flush 

wall box (not supplied)

Use a Std. 2 gang 25mm

deep surface mounted

wall box (not supplied)

Fused Spur 
240V Mains Input

To next Zone 2 wall sensor
detector* (max 4 detectors
each zone)

To next Zone 1 wall sensor

detector* (max 4 detectors

each zone)

To Zone 2 Lights

To Zone 1 Lights

1 way terminal block supplied

for earth termination (insulate

and locate inside wall box)

Zone 1 wall

sensor detector

Zone 2 wall

sensor detector

Zone linking selector

Use PVC insulated twin and earth cable 1.5mm

2

*Use low voltage 2 core

cable (sleeving supplied

to insulate cable run

inside switch

MULTI SENSOR SWITCH

1 WAY TERMINAL BLOCK

180° WALL SENSOR DETECTOR

Light on time adjuster

Light level adjuster

(zones 1 & 2)

LED

indicator

Operating mode

selector

Pack Contents

NOTE: Wall mounting fixing screws and

wallplugs for the Wall Sensor Detector are not

supplied. Use 2 X No 8 11/2" (40mm) screws

(for earth termination – see wiring section)

2 x 40mm CHROME SCREWS

(to secure Multi Sensor Switch to wall box –

see installing switch section)

2 x 165mm LONG PVC INSULATION SLEEVES

(to insulate low voltage 2 core cable inside

switch – see wiring section)

Installing the Multi Sensor Switch

Wall Mounting

The Multi Sensor Switch is for internal siting only and can be either flush
mounted or surface mounted onto an interior wall.

Surface Mounted

Wiring

INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT DIY
PERSON. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN. 
THE MAINS SUPPLY TO THE UNIT SHOULD BE FUSED AT:
3 AMPS -

Light loads up to 500W

13 AMPS -

Light loads between 500-1500W

AND ALSO INCORPORATE AN ON/OFF SWITCH
It must be possible to isolate the supply completely for
installation/maintenance purposes. This can be done by an isolating switch or
at the mains supply switch to the  premises.
BEFORE WIRING THE MULTI SENSOR SWITCH ENSURE THAT THE
MAINS IS DISCONNECTED AT SOURCE.

Cable Plan

For mains IN and switched mains OUT (to lights) – use PVC insulated twin and
earth cable 1.5mm

2

.  For Wall Sensor Detector connection (zone 1 and zone 2) –

use low voltage 2 core cable (bell wire). IMPORTANT: Use the two strips of
sleeving supplied to insulate the low voltage cable run inside the switch.

Flush Mounted

General

A passive infra-red Multi Sensor Switch and 180° sensor-detector, providing security
lighting control in either 1 or 2 zones. The wall switch is designed to be sited internally
on new or existing installations and operates in conjunction with low-voltage SL099
sensor detectors, mounted externally. Each zone is fully independent and can control
up to 4 sensor-detectors and up to 1500W of lighting. Simple slide-switch controls
allow automatic passive infra-red security or manual ON/OFF operation in both
individual zones. An audible alarm (optional setting) with LED indication sounds on
detection. Light-on-times are adjustable from 5 seconds to 5 minutes in each zone and
a light level control allows dusk till  dawn and daylight operation. 

INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT DIY PERSON. IF
IN DOUBT CONSULT A QUALIFIED ELECTRICIAN. PLEASE READ THE
INSTRUCTIONS THOROUGHLY BEFORE COMMENCING WORK.

SAFETY  The electricity supply must be disconnected whilst carrying out the installation.

Max 1500W of

lighting each zone

Содержание SL055

Страница 1: ...PA S S I V E I N F R A R E D M U LT I S E N S O R S W I T C H D E T E C T O R Cat No SL055 I N S T A L L A T I O N O P E R A T I N G I N S T R U C T I O N S S ...

Страница 2: ...m screws for earth termination see wiring section 2 x 40mm CHROME SCREWS to secure Multi Sensor Switch to wall box see installing switch section 2 x 165mm LONG PVC INSULATION SLEEVES to insulate low voltage 2 core cable inside switch see wiring section General Apassiveinfra redMultiSensorSwitchand180 sensor detector providingsecurity lightingcontrolineither1or2zones Thewallswitchisdesignedtobesite...

Страница 3: ...he day and night operation Turn adjuster arrow anti clockwise for a darker start operation NOTE Thereisonlyonelightleveladjustercontrollingbothzones Thewallsensor detectorconnectedtozone1withinthedarkestlitareasetsthelightlevel Audible Alarm Selector OFF Independent to each zone Internal buzzer alarm permanently OFF The internal buzzer alarm will sound for approx 1 second each time movement is det...

Страница 4: ...witch is for internal siting only and can be either flush mounted or surface mounted onto an interior wall Surface Mounted Wiring INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT DIY PERSON IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN THE MAINS SUPPLY TO THE UNIT SHOULD BE FUSED AT 3 AMPS Light loads up to 500W 13 AMPS Light loads between 500 1500W AND ALSO INCORPORATE AN ON OFF SWITCH It must be ...

Страница 5: ...g at 2 5 metres 180 Down Maximum setting at 15 metres 180 Refer to detection range iv Once the range is established lock the terminal block into position by tightening the field adjustment screw v Replace front cover and secure with cover screw Wiring All Wall Sensor Detectors should be wired in parallel back to the Multi Sensor Switch terminals zone 1 and 2 refer to Multi Sensor Switch cable plan...

Страница 6: ... Switch is for internal siting only Wall Sensor Detectors are mounted externally Use the 2 strips of insulating sleeve supplied to insulate the 2 core low voltage cable run inside the Multi Sensor Switch Wall Sensor Detectors should be mounted at a height of 2 5 metres At this height the detector can be adjusted within minimum and maximum settings Refer to adjust detection range setting Set light ...

Страница 7: ...INE 020 8450 0515 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com Designed and manufactured in the U K 67 057 45 2 ...

Отзывы: