Light ON Time Adjuster
Sets the length of time the light(s) remain on after detection by a Wall Sensor
Detector
Turn adjuster arrow anti-clockwise for minimum on time.
Turn adjuster arrow clockwise for a longer time on period.
Timing is adjustable from approx 5 seconds to 5 minutes.
Zone Link
Both zones can be linked via a removable selector link on the back of the
switch.
ZONE LINK OFF - Light on times operate independently of
each other.
ZONE LINK ON - Light on times are governed by the zone set
with the longest light on time period. All Wall Sensor Detectors
in either zone will operate the system with this link
Light Level Adjuster
The adjustable light level control (100 Lux – 5 Lux determines at what part of
the day the system operates when set in AUTO (PIR) operating mode
Turn adjuster arrow fully clockwise for the day and night
operation.
Turn adjuster arrow anti-clockwise for a darker start operation.
NOTE: There is only one light level adjuster controlling both zones. The wall sensor
detector connected to zone 1 within the darkest lit area sets the light level.
Audible Alarm Selector - OFF/
(Independent to each zone)
Internal buzzer alarm permanently OFF
The internal buzzer alarm will sound for approx.
1 second each time movement is detected by a Wall
Sensor Detector. NOTE: This facility operates over a
24hr period and can function independently of the
operating mode selections (OFF/AUTO/ON) above.
To help distinguish in what zone an intrusion has
occurred. ZONE 1 buzzer sounds a Continuous
bleep – bleeeeeep ZONE 2 buzzer sounds a fast
intermittent bleep – bleepbleepbleepbleep
LED Indicator
(Independent to each zone)
OFF – LED does not show
AUTO – Led shows on detection of movement
detected by the Wall Sensor Detector. The indicator
will remain on for the same period as the light on
time selector. (see light on time adjuster.)
ON – LED remains permanently ON.
Multi Sensor Switch Controls
Each of the zone controls are independent of each other allowing individual
zone settings or combined operation. NOTE: There is only one light level
adjuster for both zones which is set in conjunction with the sensor detector
connected to zone 1 in the darkest lit area.
Operating Mode Selector OFF/Auto/ON
(Independent to each zone)
Light(s) permanently OFF
Light(s) operational in conjunction with PIR Wall
Sensor Detectors
Light(s) permanently ON
4
3
6
5
2
1
Operating mode
selector
ZONE 2
CONTROLS
ZONE 1
CONTROLS
Audible
alarm
selector
Audible
alarm
selector
40mm
Chrome
screw
40mm
Chrome
screw
LED
indicator
Light on time adjuster
40mm chrome screws
40mm chrome screws
Multi Sensor switch
Multi Sensor switch
Use a Std. 2 gang 25mm deep metal flush
wall box (not supplied)
Use a Std. 2 gang 25mm
deep surface mounted
wall box (not supplied)
Fused Spur
240V Mains Input
To next Zone 2 wall sensor
detector* (max 4 detectors
each zone)
To next Zone 1 wall sensor
detector* (max 4 detectors
each zone)
To Zone 2 Lights
To Zone 1 Lights
1 way terminal block supplied
for earth termination (insulate
and locate inside wall box)
Zone 1 wall
sensor detector
Zone 2 wall
sensor detector
Zone linking selector
Use PVC insulated twin and earth cable 1.5mm
2
*Use low voltage 2 core
cable (sleeving supplied
to insulate cable run
inside switch
MULTI SENSOR SWITCH
1 WAY TERMINAL BLOCK
180° WALL SENSOR DETECTOR
Light on time adjuster
Light level adjuster
(zones 1 & 2)
LED
indicator
Operating mode
selector
Pack Contents
NOTE: Wall mounting fixing screws and
wallplugs for the Wall Sensor Detector are not
supplied. Use 2 X No 8 11/2" (40mm) screws
(for earth termination – see wiring section)
2 x 40mm CHROME SCREWS
(to secure Multi Sensor Switch to wall box –
see installing switch section)
2 x 165mm LONG PVC INSULATION SLEEVES
(to insulate low voltage 2 core cable inside
switch – see wiring section)
Installing the Multi Sensor Switch
Wall Mounting
The Multi Sensor Switch is for internal siting only and can be either flush
mounted or surface mounted onto an interior wall.
Surface Mounted
Wiring
INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT DIY
PERSON. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN.
THE MAINS SUPPLY TO THE UNIT SHOULD BE FUSED AT:
3 AMPS -
Light loads up to 500W
13 AMPS -
Light loads between 500-1500W
AND ALSO INCORPORATE AN ON/OFF SWITCH
It must be possible to isolate the supply completely for
installation/maintenance purposes. This can be done by an isolating switch or
at the mains supply switch to the premises.
BEFORE WIRING THE MULTI SENSOR SWITCH ENSURE THAT THE
MAINS IS DISCONNECTED AT SOURCE.
Cable Plan
For mains IN and switched mains OUT (to lights) – use PVC insulated twin and
earth cable 1.5mm
2
. For Wall Sensor Detector connection (zone 1 and zone 2) –
use low voltage 2 core cable (bell wire). IMPORTANT: Use the two strips of
sleeving supplied to insulate the low voltage cable run inside the switch.
Flush Mounted
General
A passive infra-red Multi Sensor Switch and 180° sensor-detector, providing security
lighting control in either 1 or 2 zones. The wall switch is designed to be sited internally
on new or existing installations and operates in conjunction with low-voltage SL099
sensor detectors, mounted externally. Each zone is fully independent and can control
up to 4 sensor-detectors and up to 1500W of lighting. Simple slide-switch controls
allow automatic passive infra-red security or manual ON/OFF operation in both
individual zones. An audible alarm (optional setting) with LED indication sounds on
detection. Light-on-times are adjustable from 5 seconds to 5 minutes in each zone and
a light level control allows dusk till dawn and daylight operation.
INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT DIY PERSON. IF
IN DOUBT CONSULT A QUALIFIED ELECTRICIAN. PLEASE READ THE
INSTRUCTIONS THOROUGHLY BEFORE COMMENCING WORK.
SAFETY The electricity supply must be disconnected whilst carrying out the installation.
Max 1500W of
lighting each zone