8
11
Setting Up for Automatic Operation (Auto Mode)
• When walk tests are complete, the unit can be adjusted
for automatic operation.
• The TIME ON adjustment controls how long the unit remains
illuminated following activation and after all motion ceases.
• Use a thin flat blade screwdriver to make adjustments.
• This can be set between 2 seconds to a maximum of 30 minutes.
• Set the control to the desired setting between these limits.
• The LUX Level adjustment determines the level of darkness required for the unit
to start operating. The setting is best achieved by the procedure below;
1 Set the LUX Level adjustment knob fully clockwise (Sun symbol).
2. When the ambient light level reaches the level of darkness at which you wish
the lamp to become operative (i.e. at dusk) SLOWLY rotate the control in an
anti-clockwise direction until a point is reached where the lamp illuminates.
3 Leave the control set at this point.
• At this position the unit should become operative at approximately
the same level of darkness each evening.
• Observe the operation of the unit. If the unit is starting to operate too early
(i.e. when it is quite light) adjust the control slightly anti-clockwise.
If the unit starts to operate too late (i.e. when it is very dark).
Adjust the control slightly clockwise.
• Continue to adjust until the unit operates as desired.
• Reposition the front cover
over the PIR sensor
(See image 11).