•  The unit will now operate during daytime as well as at night, illuminating the 

lamp for approx. 2 seconds each time. This allows testing to be carried out to 
establish whether the sensor is covering the required area.

•  Walk across the location the sensor is fitted, to establish the detection zone.
•  The sensor will detect you approximately up to 10 meters forward at mounting 

height of 2.5m.

•  As you cross the detection “zone” the lamp will illuminate. Now stand still  

until the lamp extinguishes (this should take approx. 2 seconds).

•  Start moving again after 5 seconds. Each time you cross the detection “zone” 

the lamp will illuminate.

•  Repeat the above, walking at various distances and angles to the unit.  

This will help you to confirm the detection pattern.

Setting Up for Automatic Operation (Auto Mode)

•  When walk tests are complete, the unit can be adjusted for automatic operation.
•  The TIME ON adjustment controls how long the unit remains illuminated 

following activation and after all motion ceases. 

•  Use a thin flat blade screwdriver to make adjustments. We recommend using 

the knob adjuster included in the accessory pack to adjust the Time and Lux 
settings, however a thin flat head screwdriver or a 2.5mm Allen key  
could also be used.

•  This can be set between 2 seconds to a maximum of 30 minutes.
•  Set the control to the desired setting between these limits.
•  The LUX Level adjustment determines the level of darkness required for the unit 

to start operating. The setting is best achieved by the procedure below;

  1.  Set the LUX Level adjustment knob fully clockwise (Sun symbol). 
  2.  When the ambient light level reaches the level of darkness at which you  

  wish the lamp to become operative (i.e. at dusk) SLOWLY rotate the  
  control in an anti-clockwise direction until a point is reached where  
  the lamp illuminates. 

  3.  Leave the control set at this point.
•  At this position the unit should become operative at approximately  

the same level of darkness each evening.

•  Observe the operation of the unit. If the unit is starting to operate  

too early (i.e. when it is quite light) adjust the control slightly anti-clockwise.  

Содержание LED200PIRBE

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 2x 10W LED Slimline PIR Floodlight Twin Flood Model LED200PIRBE Black Model LED200PIRWHE White ...

Страница 2: ...ed does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz This luminaire is of class I construction and must be earthed 2x 10W LED Non replaceable lamp Energy Usage 20KwH 1000H Lumen Output 2x 840lm Motion Detection Range Up to 10m at 2 5m mounting height Detection Angle 180 Lamp Adjustment Pan and Tilt Wall Mount Pan Outward 21 limited by w...

Страница 3: ...N time Back Box Mounting Centres 60mm IP55 Rated suitable for restricted external applications CE Compliant Dimensions H 160mm W 167mm D 50mm Other Loads External Slave LED Lamp Max 100W Halogen Lamp Max 300W Fluorescent Lamp Max 200W Parallel Switching A maximum of 4 LED200PIR twin floodlights can be wired in parallel to enable any detector to turn ON all the lights connected Note if you have the...

Страница 4: ...o movement directly TOWARDS See image C Therefore position the floodlight so that its PIR sensor looks ACROSS the likely approach path Avoid positioning the floodlight where there are any sources of heat in the detection area of its PIR sensor extractor fans tumble dryer exhausts etc including opposite any other light sources such as other security floodlights Reflective surfaces i e pools of wate...

Страница 5: ...on the wall using the back box as a template See image 4 Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plugs into the holes Pass the 230V 50Hz supply and load cables through the cable entry points on the back box ensuring the grommets are used to maintain the IP rating of the luminaire 2 3 4 5 5 6 Fix the...

Страница 6: ... image 6 ensuring correct polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram for wiring details 5 8 Re connect the luminaire to the back box ensuring the 2 lugs firmly latch on the left and right hand side indicated by a click See image 7 ...

Страница 7: ...terminal block on the back box as follows Live Supply Brown or Red to L Neutral Supply Blue or Black to N Earth Green Yellow to For additional external slave lighting connect the external load to the terminal block on the back box as follows Live Supply Brown or Red to L1 Neutral Supply Blue or Black to N Earth Green Yellow to ...

Страница 8: ... PIR sensor is set to Test Mode i e the TIME ON Adjustment to the minimum fully anti clockwise and the Lux Level set the Sun symbol fully clockwise We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settings however a thin flat head screwdriver or a 2 5mm Allen key could also be used Turn the power to the unit ON See image 8 The lamp will immediately ill...

Страница 9: ...lowing activation and after all motion ceases Use a thin flat blade screwdriver to make adjustments We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settings however a thin flat head screwdriver or a 2 5mm Allen key could also be used This can be set between 2 seconds to a maximum of 30 minutes Set the control to the desired setting between these limit...

Страница 10: ...2 seconds The floodlight will now illuminate continuously for 6 hours or until it is switched back into Auto Mode If the unit starts to operate too late i e when it is very dark Adjust the control slightly clockwise Continue to adjust until the unit operates as desired 8 Lamp Adjustment Pan Tilt adjustment including details when using the optional spacer and corner brackets sold separately or Thin...

Страница 11: ... responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent You are able to add an additional 6 hours ON time by switching the internal wall switch again twice OFF ON OFF ON within 2 seconds To return to Auto Mode switch the internal wall switch once OFF ON within 2 seconds The floodlight will return to Auto Mode and wil...

Страница 12: ... csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in resolving your query HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com ...

Отзывы: