4
5.2 An isolating switch should be installed to
enable the power to be switched ON and OFF
for maintenance purposes and to activate the
manual/auto override function.
5.3 Disconnect the back box from the luminaire
by releasing the lugs (left or right side).
See Image 2.
5.4 Firmly grip the back box with your hand,
from top and bottom and carefully pull
away from the luminaire. See Image 3.
5.5 Mark the position of the mounting holes
on the wall using the back box as a template
(See image 4). Drill the holes ensuring not to
infringe with any gas/water pipes or electrical
cables that may be hidden below the surface.
Insert the rawl plugs into the holes. Pass the
230V 50Hz supply and load cables through
the cable entry points on the back box,
ensuring the grommets are used to maintain
the IP rating of the luminaire.
2
3
4
5
5.6 Fix the back box to the wall using the 2 mounting screws, making sure
it is the correct way up. Take care not to over-tighten the screws to prevent
damage to the back box. If using a power screwdriver, use the lowest
torque setting. See image 5.