TEST MODE - THREE LEDS VISIBLE

The lamp will now illuminate for approximately 2 seconds every time movement is detected.

Walk across the detection area approximately 5 metres from the unit. Each time you are 

detected the lamp will illuminate. Now stand still until the lamp extinguishes (this should 

take approx. 2 seconds)

Start moving again, when you are detected again the lamp will illuminate.

Repeat the above, walking at various angles and distances to the unit. This will help you to 

establish the detection pattern.

If the detection area is too small for your requirements, try angling the sensor head up.

Angling the head downwards will reduce the detection area should a smaller range be 

required.

SETTING UP FOR AUTOMATIC OPERATION - 3 SCROLLING LED’S VISIBLE

When walk tests are complete, the unit will be switch into Automatic Mode.

Simply cease movement within the detection area for approximately 60 seconds. The unit 

will then switch to Automatic Mode, this is indicated by the illumination of three scrolling 

LEDS in the top transparent area of the sensor head. These LED's will scroll from left to right 

during daylight and darkness.

The TIME setting controls how long the unit remains illuminated following activation and 

after all motion ceases.

(See diagram G. the time adjustment knob is indicated by the "Clock" symbol).

 The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time 

(fully clockwise) is approx. 5 minutes. Set the control to the desired setting between these 

limits.

The DUSK control determines the level of darkness required for the unit to start operating. 

The setting is best achieved by the procedure below:

(See diagram G. the Dusk adjustment knob is indicated by the "Moon" and "Sun symbols).

Set the DUSK control knob fully anti clockwise. Wait until darkness falls.

When the ambient light level reaches the level of darkness at which you wish the lamp to 

become operative (i.e.: at dusk) SLOWLY rotate the control in a clockwise direction until a 

point is reached where the lamp illuminates. Leave the control set at this point.

At this position the unit should become operative at approximately the same level of 

darkness each evening. Observe the operation of the unit. If the unit is starting to operate 

too early (i.e.: when it is quite light) adjust the control slightly anti-clockwise. If the unit 

starts to operate too late (i.e.: when it is very dark). Adjust the control slightly clockwise.

Continue to adjust until the unit operates as desired.

The LED's will scroll from left to right, day and night; indicating the unit is in Automatic 

Mode. The LED's will extinguish when the PIR activates the light for as long as the lamp is 

illuminated.

MASKING THE SENSOR LENS

To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor 

lens using the masks provided in the accessory pack (see diagram H). For your information, 

the top section of the lens covers long range detection, the bottom covers short range. 

Similarly the left and right lens sections cover the left and right detection areas respectively.

MANUAL OVERRIDE MODE - SINGLE LED ILLUMINATED

The light can be switched on for longer time periods by use of the Manual Override Mode. 

This can be activated at night by using the internal wall switch or circuit breaker.

Switch the internal wall switch/circuit breaker twice (on/off, on/off) within 2 seconds. The 

unit will now illuminate continuously until dawn or until it is switched back into Auto 

Mode.

Содержание MLB150C

Страница 1: ...N o p e r atin g inst r u c tions 500W multi Pir Halogen floodlight Cat No MLB500C Black Cat No MLW500C White 150W multi Pir Halogen floodlight Cat No MLB150C Black Cat No MLW150C White Installation O...

Страница 2: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Страница 3: ...screws to prevent damage to the mounting plate If using a power screwdriver use the lowest torque setting IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switchin...

Страница 4: ...Place this edge against walland use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length NOT TO SCALE...

Страница 5: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Holiday Mode Time...

Страница 6: ...are factory set Lux is set to the moon setting and Time is set to a minimum fully anti clockwise see diagram G Turn the power to the unit on The lamp will illuminate for approximately 30 seconds This...

Страница 7: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Страница 8: ...quired See diagram G the adjustment knob is identified by the letter T inside a circle Do not adjust this setting if you do not wish to use the Holiday Mode facility This time adjustment is factory se...

Страница 9: ...the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light leve...

Страница 10: ...only when motion is detected Automatic Mode is indicated by scrolling LEDs from Left to right You may not be allowing the unit time to complete it s warm up period Stand well out of the detection ran...

Страница 11: ...the current DUSK setting During daylight adjust the DUSK control slightly anti clockwise When the lamp load extinguishes enter the detection area If the PIR still activates the setting is still too hi...

Страница 12: ...ne timeguard com For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A Group company For assistance with the p...

Отзывы: