SECTION THREE

INSTALLATION

After choosing a suitable location (see previous section) install the unit as follows:

Remove the wiring box cover by unscrewing the retaining screw (fig F) and with a 
screwdriver gently push down and ease out.
The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 
3-core round flexible cable of 1mm2 gauge is used. An isolating switch should be installed 
to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off 
when not required or for maintenance purposes.

Mark the position of the fitting holes.  

Drill the holes. Insert the rawl plugs into the holes.

PIERCE & PASS THE CABLE(S) THROUGH THE GROMMET(S) BEFORE PROCEEDING.

Fix the mounting plate to the wall.  Take care not to overtighten the screws to prevent 
damage to the mounting plate.  If using a power screwdriver, use the lowest torque setting.

*** IMPORTANT ***

Switch off the electricity at the fuse box by removing the relevant fuse or 

switching off the circuit breaker before proceeding with the installation.

CONNECTION

This unit is supplied with a hanging attachment (tether) to aid installation.
If it is not required, simply remove from the unit and discard.

Place the round end of the tether into the keyhole shape location hole on the wall bracket. 
Ensure the tether is securely fixed into the slot before releasing the weight of the unit.

The unit can now be suspended below the wall bracket. (Fig D)

Connect the cable to the terminal block as follows (see connection diagram):

NEUTRAL (Blue)  

 

N

EARTH (Green/Yellow) 
LIVE (Brown) 

 

L

Ensure the connections are secure.

Place terminal block onto its securing pillar on the wall bracket (Fig E)

Remove and discard the tether.

Fit floodlight to wall bracket and secure by fixing screw (Fig F)

Содержание MLB150C

Страница 1: ...N o p e r atin g inst r u c tions 500W multi Pir Halogen floodlight Cat No MLB500C Black Cat No MLW500C White 150W multi Pir Halogen floodlight Cat No MLB150C Black Cat No MLW150C White Installation O...

Страница 2: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Страница 3: ...screws to prevent damage to the mounting plate If using a power screwdriver use the lowest torque setting IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switchin...

Страница 4: ...Place this edge against walland use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length NOT TO SCALE...

Страница 5: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Holiday Mode Time...

Страница 6: ...are factory set Lux is set to the moon setting and Time is set to a minimum fully anti clockwise see diagram G Turn the power to the unit on The lamp will illuminate for approximately 30 seconds This...

Страница 7: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Страница 8: ...quired See diagram G the adjustment knob is identified by the letter T inside a circle Do not adjust this setting if you do not wish to use the Holiday Mode facility This time adjustment is factory se...

Страница 9: ...the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light leve...

Страница 10: ...only when motion is detected Automatic Mode is indicated by scrolling LEDs from Left to right You may not be allowing the unit time to complete it s warm up period Stand well out of the detection ran...

Страница 11: ...the current DUSK setting During daylight adjust the DUSK control slightly anti clockwise When the lamp load extinguishes enter the detection area If the PIR still activates the setting is still too hi...

Страница 12: ...ne timeguard com For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A Group company For assistance with the p...

Отзывы: