Time Guard MLB150C Скачать руководство пользователя страница 11

PROBLEM

o

 

 PIR sensor will not operate 

at all.

o

 

 The PIR sensor will not 

operate at night.

o

 

 Unit activates during the 

daytime

o

 

PIR coverage is poor/

sporadic

o

 

 Detection range varies 

from day to day
 

SOLUTION

Check that the power is switched ON at the circuit breaker/
internal wall switch.

Turn OFF the power to the unit and check the wiring 
connections as per the diagram (see previous section 3). 
Ensure no connections are loose.

Check the lamp. If the lamp has failed, replace. Ensure that 
the lamp is seated correctly in the lampholder.

The level of ambient light in the area may be too bright to 
allow operation at the current DUSK setting. During the 
hours of darkness, adjust the DUSK control slowly 
clockwise until the lamp illuminates. Refer to previous 
section for more details.

The level of ambient light in the area may be too dark for 
the current DUSK setting. During daylight, adjust the DUSK 
control slightly anti-clockwise. When the lamp load 
extinguishes, enter the detection area. If the PIR still 
activates, the setting is still too high. Repeat the above 
procedure until the PIR does not activate when you enter 
the detection area. Refer to previous section for more 
details.

Unit may be poorly located. See previous section - 
‘Selecting The Location’ and re-locate the unit.

PIR sensors are influenced by climatic conditions. The 
colder the ambient temperature, the more effective  
the sensor will be. You may need to make seasonal 
adjustments to the sensor head position to ensure  
trouble-free operation all year round.

In the unlikely event of this product becoming faulty due  
to defective material or manufacture, within 5 years of the 
date of purchase, please return it to your supplier in the 
first year with proof of purchase and it will be replaced free 
of charge. For years 2 to 5 or any difficulty in the first year 
telephone our helpline on 020 8450 0515.

5 YEAR

GUARANTEE

Содержание MLB150C

Страница 1: ...N o p e r atin g inst r u c tions 500W multi Pir Halogen floodlight Cat No MLB500C Black Cat No MLW500C White 150W multi Pir Halogen floodlight Cat No MLB150C Black Cat No MLW150C White Installation O...

Страница 2: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Страница 3: ...screws to prevent damage to the mounting plate If using a power screwdriver use the lowest torque setting IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switchin...

Страница 4: ...Place this edge against walland use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length NOT TO SCALE...

Страница 5: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Holiday Mode Time...

Страница 6: ...are factory set Lux is set to the moon setting and Time is set to a minimum fully anti clockwise see diagram G Turn the power to the unit on The lamp will illuminate for approximately 30 seconds This...

Страница 7: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Страница 8: ...quired See diagram G the adjustment knob is identified by the letter T inside a circle Do not adjust this setting if you do not wish to use the Holiday Mode facility This time adjustment is factory se...

Страница 9: ...the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light leve...

Страница 10: ...only when motion is detected Automatic Mode is indicated by scrolling LEDs from Left to right You may not be allowing the unit time to complete it s warm up period Stand well out of the detection ran...

Страница 11: ...the current DUSK setting During daylight adjust the DUSK control slightly anti clockwise When the lamp load extinguishes enter the detection area If the PIR still activates the setting is still too hi...

Страница 12: ...ne timeguard com For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A Group company For assistance with the p...

Отзывы: