SECTION THREE
INSTALLATION
After choosing a suitable location
(see previous section) install the unit
as follows:
Remove the wiring box cover by unscrewing the retaining screw (fig F) and with a
screwdriver gently push down and ease out.
The unit is suitable for connection to a 230 V ac 50Hz electricity supply. it is suggested that
3-core round flexible cable of 1mm2 gauge is used. A isolating switch should be installed to
switch the power to the unit On & OFF. This allows the sensor to be easily switched off
when not required or for maintenance purposes.
Mark the position of the fitting holes.
Drill the holes. insert the rawl plugs into the holes.
PIERCE & PASS THE CABLE(S) THROUGH THE GROMMET(S) BEFORE PROCEEDING.
Fix the mounting plate to the wall. Take care not to overtighten the screws to prevent
damage to the mounting plate. if using a power screwdriver, use the lowest torque setting.
*** IMPORTANT ***
Switch off the electricity at the fuse box by removing the relevant fuse or
switching off the circuit breaker before proceeding with the installation.
CONNECTION
This unit is supplied with a hanging attachment (tether) to aid installation.
if it is not required, simply remove from the unit and discard.
place the round end of the tether into the keyhole shape location hole on the wall bracket.
ensure the tether is securely fixed into the slot before releasing the weight of the unit.
The unit can now be suspended below the wall bracket. (Fig D)
Connect the mains supply cable to the terminal block as follows (see connection diagram):
neUTRAL (Blue)
n
eARTH (Green/Yellow)
LiVe (Brown)
L
Connect the cable from the lighting load to the terminal block on the unit as follows: (see
connection diagram)
neUTRAL (Blue)
n
eARTH (Green/Yellow)
LiVe (White)
L1
ensure the connections are secure.
place terminal block onto its securing pillar on the wall bracket (Fig e)
Remove and discard the tether.
Fit control to wall bracket and secure by fixing screw (Fig F)