HOLIDAY MODE

Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) within 2 seconds. 
A single flashing red LeD at the top of the sensor head indicates Holiday Mode.

The unit will now illuminate for a user defined time between 1 and 8 hours. The time can be 
set by rotating the centre adjustment knob as required. (See diagram G, the adjustment knob 
is identified by the letter T inside a circle.)

Do not adjust this setting if you do not wish to use the Holiday Mode facility.
This time adjustment is factory set to 1 hour.

please note: Fully anticlockwise is 1 hour, fully clockwise is 8 hours.

After the defined period has elapsed, the unit will return to Automatic Mode and operate as 
previously set up and the three scrolling LeD's will illuminate from left to right.

Holiday Mode will nOT reset to Automatic Mode at dawn, it will repeat each night until reset 
by the user.

To cancel Holiday Mode, switch the internal wall switch/circuit breaker once (off/on) within 
one second. The unit will turn to Automatic Mode indicated by the scrolling LeDs.

SECTION FIVE

TECHNICAL SPECIFICATIONS

Detection Range 

 

 
Detection Angle 

 

 

 

Power Supply 

 

 
Maximum Switchable Load

Time On Adjustment   

Dusk Level Adjustment 
 
Environmental Protection

EC Directives

Up to 12 metres

200º
 

 

230 V AC ~ 50Hz

3000W Filament/Incandescent  
or 500W Fluorescent/Low Energy

5 seconds - 18 minutes

Day & night or night only operation

IP55 (suitable for outdoor use)

Conforms to 73/23/EEC. 89/336/EEC

If you experience problems refer to Troubleshooting Guide.

If problems still exist, do not immediately return the unit to store. 

Telephone the Timeguard Customer Helpline

020 8450 0515

Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.

Содержание 5012483010853

Страница 1: ...I N S T A L L A T I O N o p e r atin g inst r u c tions 3000W multi Pir light controller Cat No MLB3000 Black Cat No MLW3000 White Installation Operating Instructions...

Страница 2: ...iagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful position...

Страница 3: ...lowest torque setting IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation CONNECTION This un...

Страница 4: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Страница 5: ...Place this edge against wall and use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length NOT TO SCALE...

Страница 6: ...he unit Each time you are detected the lamp will illuminate Now stand still until the lamp extinguishes this should take approx 2 seconds Start moving again when you are detected again the lamp will i...

Страница 7: ...he light for as long as the lamp is illuminated MASKING THE SENSOR LENS To restrict the sensor coverage preventing detection in unwanted areas mask the sensor lens using the masks provided in the acce...

Страница 8: ...rom left to right Holiday Mode will NOT reset to Automatic Mode at dawn it will repeat each night until reset by the user To cancel Holiday Mode switch the internal wall switch circuit breaker once of...

Страница 9: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Holiday Mode Time...

Страница 10: ...ch the internal wall switch circuit breaker off on with one second and the unit will return to Automatic Mode The light will illuminate only when motion is detected Automatic Mode is indicated by scro...

Страница 11: ...or more details Unit may be poorly located See previous section Selecting The Location and re locate the unit PIR sensors are influenced by climatic conditions The colder the ambient temperature the m...

Страница 12: ...ne timeguard com For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A Group company For assistance with the p...

Отзывы: