6
If the lights did not go OFF in step 4 on page 5 the Rx
is not picking up a signal. Check the radio signal path
between the Sensor and Receiver for any metal
obstructions (support beams, chain link fences
etc).These can block radio signals and interfere with
signal transmission. A way to check path if using the
Battery Powered Detector TLTXDCB is to set the Rx On
time dial to test, remove the sensor from its location
and walk the sensor around the Rx. As you walk, wave
your hand in front of the sensor Tx. Note when it turns
the Rx light ON, and re mount in that area.
Settings
After Programming, set the ON TIME dial.
To set how long the lamp will remain on after the
TLRX150B/500B has received a signal, set the ON
TIME dial on it to 1, 3 , 5 or 12 minutes. See fig D.
Manual override
The lamp can be turned on and off independently of
any transmission signal by switching the unit off/on
once in less than two seconds To return to Auto Mode
repeat the switching action.
Erasing all codes
Tx unit codes can be erased for reprogramming.
To erase codes, while TLRX150B/500B is powered,
press and hold the PROGRAM button for more than 5
seconds. The light will turn on, go out and then turn on
again. This will clear the unit of all programmed codes
and place it back into the PROGRAMMING Mode.
Now return to the Programming Section.
m