7085A Temperature Distribution and 10 Channel Scanner Module 

v1.1 

7085A Temperature Distribution and 10 Channel Scanner Module

 

Page 6 of 21

 

2

 

Operation 

2.1

 

Operational Guidelines 

The 7085A is designed to be used with the 7051 module or the 8060 Module that features 
the AVM65 option (standard with 8060+ version). Note the 7085A interfaces with the integral 
multimeter section of both modules.  
The purpose of the 7085A is to enable users to automate temperature calibration 
applications. For full usability a compatible Time Electronics Dry Block Calibrator and 
EasyCal Software must be used. 

Note: The 7085A cannot be used with the standard measure function of the 8060. It must be connected and 

operated via the AVM65 measure section and EasyCal software.  

 

2.2

 

Using Time Electronics Dry Block Calibrators 

The Time Electronics range of dry block calibrators can be driven by EasyCal software to 
automate testing procedures. Standard models feature a USB port that can be connected to 
the CalBench control centre via the under section of the primary console. Some legacy model 
dry block calibrators feature RS-232 communication, this is also connected under the console.  
When a CalBench is ordered with a compatible dry block calibrator and module with 
EasyCal, the software drivers are included as standard. 

  

Note:

 Some dry block calibrators have comms 

ports on the side of the unit. 

Содержание 7085A

Страница 1: ...and 10 Channel Scanner Module Version 1 1 March 2021 Time Electronics Ltd Unit 5 TON Business Park 2 8 Morley Road Tonbridge Kent TN9 1RA United Kingdom T 44 0 1732 355993 F 44 0 1732 350198 mail tim...

Страница 2: ...Electronics Ltd This also applies to any schematics drawings and diagrams contained herein This manual provides operating and safety instructions for the Time Electronics product To ensure correct op...

Страница 3: ...s 5 2 Operation 6 2 1 Operational Guidelines 6 2 2 Using Time Electronics Dry Block Calibrators 6 2 3 Thermocouple and RTD Connection 7 2 4 Cold Junction Compensation CJC 8 2 5 Connection to 7051 or 8...

Страница 4: ...urements the cold junction compensation is equipped to improve accuracy and is shown via an LCD display on the module and factored by EasyCal software via internal communication during applications Th...

Страница 5: ...le A reference thermocouple can be used by connecting to input 8 on the module Internal Connections Integral to the CalBench console for communication with compatible modules Maximum AC Voltage 125 V...

Страница 6: ...ware must be used Note The 7085A cannot be used with the standard measure function of the 8060 It must be connected and operated via the AVM65 measure section and EasyCal software 2 2 Using Time Elect...

Страница 7: ...TD probe connector 3 wire RTD Connector or 4 wire terminal block Thermocouple channels 1 to 8 are shared with the 4mm terminals 1 to 8 The RTD input channels are shared with channels 9 and 10 4 wire i...

Страница 8: ...nner Module Page 8 of 21 2 4 Cold Junction Compensation CJC The 7085A has a temperature display on the module EasyCal software automatically reads the CJC from the 7085A in the testing application Whe...

Страница 9: ...erature Distribution and 10 Channel Scanner Module v1 1 7085A Temperature Distribution and 10 Channel Scanner Module Page 9 of 21 2 5 Connection to 7051 or 8060 Modules 2 5 1 7051 Module 2 5 2 8060 Mo...

Страница 10: ...points created allowing time for the temperature to stabilise The 7085A automatically switches between probes under test plus reference probe if used and the readings captured by the 7051 8060 AVM DMM...

Страница 11: ...Dry Block from the Input calibrating instrument list If the reference probe is a thermocouple the type and CJC reference options are made available Channel 1 is used for the thermocouple reference pr...

Страница 12: ...ouple Type For thermocouple sensors the CJC reference and thermocouple type options are available In most cases the CJC reference is set to 7085 Use Scanner Tick this option to utilise the automatic s...

Страница 13: ...ng a reference pt100 probe to calibrate 5 thermocouples from 25 to 125 C The procedure is created using a Reference Reading for each test point Each UUT reading is then compared against the reference...

Страница 14: ...temperature is recorded The example above shows a reference test using an external probe The value shown in the main reading display 25 080 C is the value of the reference probe measured by the DMM A...

Страница 15: ...given test point recording the values In the example above thermocouple under test sensor reading 26 1 C is shown in the main reading display The limits are 2 C This is compared against the reference...

Страница 16: ...bility section of the calibration certificate Two methods are available to resolve this a Using the Edit Traceability feature in PrintCert allows the standard to be added after a calibration is perfor...

Страница 17: ...nel Scanner Module v1 1 7085A Temperature Distribution and 10 Channel Scanner Module Page 17 of 21 3 Additional Applications 3 1 Temperature Transmitters The same principals as described in the previo...

Страница 18: ...couple socket is connected in parallel with each red and black 4mm terminal Connect the 7051 source main terminals to the 4mm sockets and using a thermocouple compensating lead connect the thermocoupl...

Страница 19: ...lised in temperature calibration on the CalBench Because it is a 10 channel scanner the module can also be used for additional applications that require multi channel measurements For specific applica...

Страница 20: ...oes not apply to defects resulting from action of the user such as misuse operation outside of specification improper maintenance or repair or unauthorized modification Time Electronics total liabilit...

Страница 21: ...ork Send the instrument shipping charges paid to Time Electronics Ltd Unit 5 TON Business Park 2 8 Morley Road Tonbridge Kent TN9 1RA United Kingdom Tel 44 0 1732 355993 Fax 44 0 1732 350198 Email mai...

Отзывы: