![Time domain PulsON 440 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/time-domain/pulson-440/pulson-440_datasheet-and-user-manual_1116920042.webp)
42
DRAFT
P440 Data Sheet / User Guide
sufficient power to the P440s. Some batteries and power supplies have very poor connectors. These
connections are so flimsy that they provide power only intermittently. Consider the devices shown in
Figure 28
. The connector on the left provides a high quality connection. The one on the right will
cause endless problems. Nothing will ruin a multiday measurement campaign more completely than
a few cheap and worthless USB cables and connections.
Fig. 28: Superior connections (left) and inadequate product (right)
When providing power from USB devices do NOT use USB extension cables. There is sufficient
voltage drop across these cables that they will not provide sufficient power to drive a P440.
Two sets of pins guarantee a good connection
Nothing to insure a proper connection