background image

www.timberk.com • electric convector heater

www.timberk.com • electric convector heater

11

10

at that the “Normal” comfort mode indicator and value of the last 

set temperature will be shown on the display. While the temperature 

setting is blinking, press button  “     ”  or  “     ”  to set the desired 

temperature.

3.5. After the desired temperature is set, the last set value will be stored 

and the display will show the current temperature.

4. Select the operation mode
4.1. Press button “     ” once to select the economy operation mode, at that 

green “Economy” indicator will be illuminated on the control panel. In 

this mode the convector will automatically maintain the set economy 

mode temperature, switching on and off heating from time to time.

4.2. Press button  “     ”  twice to select the comfort operation mode, at 

that orange “Normal” indicator will be illuminated on the control panel. 

In this mode the convector will automatically maintain the set comfort 

mode temperature, switching on and off heating from time to time.

4.3. Press button “    ”  three times to select the antifreeze mode, at 

that symbol “AF” will be shown on the display. The convector will 

automatically maintain temperature within the range +5°C to +7°C, 

switching on and off heating from time to time.

5. Set the convector switch off timer function
5.1. When the convector is operating press button “      ” four times, at that 

yellow “Timer” indicator will start blinking on the control panel, and the 

display will show blinking value [0.0] or the last set value of the timer.

5.2. Press button  “      ”  or  “     ”  to set the convector switch off time, 

in increments of 1 hour, from 0 to 24 hours. The display will show the 

countdown of time left until the convector is switched off.

5.3. The set time value will be stored and in 3 seconds the system will 

automatically return to indicating the temperature value, at that yellow 

“Timer” indicator will be illuminated on the control panel.

5.4. The convector will be switched off after the timer expires, indicators on 

the control panel and temperature indication on the display will go out, 

at that red “Power” indicator will be on.

5.5. Switching off the unit or setting the timer value [0] will cancel the 

convector switch off timer function.

6. Set the convector switch on timer function
6.1. When the convector is switched off and only red “Power” indicator is 

illuminated, press button “      ”  and  “      ”  simultaneously, at that a 

sound signal will be given, yellow “Timer” indicator will start blinking on 

the control panel, and the display will show two small dots.

6.2. Press button “     ” or “     ” to set the convector switch off time, in 

increments of 1 hour, from 0 to 24 hours. The display will show the 

countdown of time left until the convector is switched on.

6.3. The set time value will be stored and then two small dots will be shown 

on the display and yellow “Timer” indicator will be illuminated on the 

control panel.

6.4. The convector will be switched on to operate in the economy mode 

after the timer expires, and will maintain the set temperature.

7. Audio signal

An audio signal is given when the convector is switched on and off, as 

well as the buttons are pressed.

8. Lock
8.1. When the convector is operating, to lock the system simultaneously 

press and hold buttons  “     ”  and  “     ”  for 3 seconds, after that 

symbol “_” will be shown on the display. In 3 seconds the temperature 

value will be shown, at that buttons on the control panel will be locked, 

and symbol “_” will be shown when they are pressed.

8.2. To unlock the system, press and hold buttons “      ” and “     ” for 3 

seconds or switch off the convector.

9. Air ionizing function

The convector is equipped with an air ionizer.

9.1. You can switch on and off the air ionizer by means of the ionizer button
        “      ”.
9.2. A blue “Ionizer” air ionizer indicator is illuminated when the air ionizer 

is switched on.

9.3. The air ionizer is a completely independent device and can operate 

even when the unit’s heating mode is off.

10. “RESTART” function

In case of a short-term power outage, the convector will be 

automatically switched on and will operate with the last user settings 

(except for timer settings) after power supply is restored.

11. Convector switching off

To switch off the convector, press and hold button “       ” on the control 

panel for 3 seconds, then set the power switch, located on the side of 

the control panel, to “OFF” position. 

Operating TEC.PS1 RCE…IN series convector heater by means of 

remote controller

1. Convector switching on

Connect the convector to electric mains by plugging the power cord 

into an electric outlet, set the power switch, located on the side of the 

control panel, to position “ON”, at that red power indicator “Power” will 

be illuminated on the control panel and a sound signal will be given, 

then press “POWER” button on the remote controller. The convector 

heater  will  be  switched  on  and  start  operating  in  the  comfort  mode                        

(“   ” symbol), with factory comfort mode temperature setting of 24°C 

and high heating power (“     ” symbol).

2. Heating power mode selection

Press “MODE” button several timer to select low or high heating power. 
“    ” symbol will be shown on the remote controller’s display if low 

heating power is selected, and “      ” symbol will be shown on the remote 

controller’s display if high heating power is selected. 

3. Temperature setting
3.1. Temperature can be set within the range +5 to +30°C, in increments 

of 1°C.

3.2. Factory setting of the comfort mode temperature is +24°C, factory 

setting of the economy mode temperature is +17°C.

3.3. To change the economy mode temperature, press “SET” button once, 

At that the “     ” economy mode symbol will be shown on the remote 

NOTE:

A small static electric charge may be accumulated on 

metal surfaces of a case in units, equipped with an 

air ionizer.
If your electric main has no grounding circuit or it is 

damaged. In this case there is a small possibility of 

electric shock from static voltage.

IMPORTANT! 

If the unit is operated without a grounding circuit or it 

is damaged, it is not recommended to switch on and 

operate the air ionizer.

controller’s display and value of the last set temperature will start 

blinking. While the temperature setting is blinking, press button “    ” or 

“      ” to set the desired temperature.

3.4. To change the comfort mode temperature, press “SET” button 

twice, at that the “    ” comfort mode symbol and value of the last set 

temperature will be shown on the remote controller’s display. While the 

temperature setting is blinking, press button “    ” or “    ” to set the 

desired temperature.

3.5. After the desired temperature is set, the last set value will be stored 

and the remote controller’s display will show the current temperature.

4. Operation mode selection
4.1. Press “SET” button once to select the economy operation mode, at 

that “       ” symbol will be shown on the remote controller’s display. In 

this mode the convector will automatically maintain the set economy 

mode temperature, switching on and off heating from time to time.

4.2. Press “SET” button twice to select the comfort operation mode, at that 
       “       ” symbol will be shown on the remote controller’s display. In this 

mode the convector will automatically maintain the set comfort mode 

temperature, switching on and off heating from time to time.

4.3. Press “SET” button four times to select the antifreeze mode, at that
     “     ” symbol will be shown on the remote controller’s display. The 

convector will automatically maintain temperature within the range 

+5°C to +7°C, switching on and off heating from time to time.

5. Convector switch off timer function setting
5.1. When the convector is operating press “SET” button three times, at 

that “     ” and “OFF” symbols will be shown on the remote controller’s 

display and time setting will start blinking.

5.2. Press “   ” or “   ” button to set the convector switch off time, in 

increments of 1 hour, from 0 to 24 hours. The remote controller’s 

display will show the countdown of time left until the convector is 

switched off.

5.3. The set time value will be stored and the remote controller’s display will 

show  “       ”  and  “OFF”  symbols.

5.4. Setting the timer value to [00] will cancel the convector switch off timer 

function.

6. Convector switch on timer function setting
6.1. When the convector is switched off and only red “Power” indicator is 

illuminated, press “SET” and “MODE” buttons simultaneously, at that  

Содержание TEC.PS1 LE 2000 IN

Страница 1: ...PGE 1500 IN TEC PS1 PGE 2000 IN TEC PS1 PGE 2500 IN TEC PS1 RCE 500 IN TEC PS1 RCE 1000 IN TEC PS1 RCE 1500 IN TEC PS1 RCE 2000 IN TEC PS1 RCE 2500 IN TEC PS1 M 500 IN TEC PS1 M 1000 IN TEC PS1 M 150...

Страница 2: ...ower cord must be repaired only in authorized service centers of the manufacturer and by skilled specialists 14 Never try to repair it on your own This may harm your health and affect the unit s guara...

Страница 3: ...57 8 7 TEC PS1 LE 500 IN 220 240 50 2 3 500 250 500 IP24 class I 476 400 57 4 0 TEC PS1 LE 1000 IN 220 240 50 4 5 1000 500 1000 IP24 class I 656 400 57 5 1 TEC PS1 LE 1500 IN 220 240 50 6 8 1500 750...

Страница 4: ...modes TEC PS1 RCE IN series convector heaters are equipped with a high precision electronic thermostat with LED display and a remote controller The unit is ready to use Connection to electric mains 1...

Страница 5: ...The convector is equipped with an air ionizer 6 1 You can switch on and off the air ionizer by means of the ionizer switch Ionizer located on the control panel 6 2 Ionizer switch illumination lights...

Страница 6: ...and will operate with the last user settings except for timer settings after power supply is restored 11 Convector switching off To switch off the convector press and hold button on the control panel...

Страница 7: ...n the comfort and economy operation modes 10 Button It is used to increase the selected value 11 Button It is used to decrease the selected value 12 programming button It is used to select preset prog...

Страница 8: ...mode enter or find a program of a day from where you want to copy your settings and select it with the use of the button When you have selected a required day press the button After that a symbol COP...

Страница 9: ...cleaned from dust and dirt For this purpose it is necessary to dismount the unit from the bracket and after cleaning it is necessary to return it to the initial position Preventive cleaning should be...

Страница 10: ...www timberk com www timberk com 19 18 imberk Timberk 220 240 1 2 3 4 5 6 7 8 1 2 9 180 10 11 12 13 14 15 16 17 18 OFF TEC PS1 M IN 19 20 21 22 23 24 25 26 27...

Страница 11: ...00 IN 220 240 50 6 8 1500 750 1500 IP24 class I 930 400 57 6 7 TEC PS1 LE 2000 IN 220 240 50 9 1 2000 1000 2000 IP24 class I 1267 400 57 8 6 TEC PS1 LE 2500 IN 220 240 50 11 4 2500 1250 2500 IP24 clas...

Страница 12: ...3 4 5 7 1 1 2 3 2 4 2 4 5 6 5 4 7 50 60 6 8 9 7 1 2 5 6 7 3 2 TL H A L B H23 TEC PS1 2500 1250 1267 400 458 350 458 188 TEC PS1 2000 1000 1267 400 458 350 458 188 TEC PS1 1500 750 930 400 290 350 290...

Страница 13: ...g 5 TEC PS1 M IN 1 POWER 2 Economy Normal 3 3 1 5 30 3 2 Heating Heating 4 5 2 3 4 5 1 220 240 2 3 4 10 2000 12 2500 50 TEC PS1 M IN TEC PS1 LE IN c LED TEC PS1 RCE IN c LED TEC PS1 PGE IN L D TEC PS1...

Страница 14: ...Timer 0 5 2 1 0 24 5 3 3 Timer TEC PS1 LE IN TEC PS1 RCE IN 1 ON Power 2 LO HI 3 3 1 5 30 1 3 2 24 17 3 3 Economy 1 2 Power 3 Normal 4 LED 5 Ionizer 6 7 LO HI 8 Economy 9 TEC PS1 LE IN TEC PS1 RCE IN...

Страница 15: ...imer 6 3 7 8 8 1 3 3 8 2 3 9 9 1 9 2 Ionizer 9 3 10 RESTART 11 3 OFF TEC PS1 RCE IN 1 ON Power POWER 24 2 MODE 3 3 1 5 30 1 3 2 24 17 3 3 SET 3 4 SET 3 5 4 4 1 SET 4 2 SET 4 3 SET 5 7 5 5 1 SET OFF 5...

Страница 16: ...7 Normal 8 L D TEC PS1 PGE IN 9 3 9 10 11 12 13 14 15 TEC PS1 PGE IN 1 ON Power 2 2 1 1 0 24 2 2 1 59 2 3 Mon Tue Wed Thu Fri Sat Sun 3 3 1 4 4 1 5 30 1 4 2 24 17 4 3 Normal 4 4 Economy 5 5 1 Normal...

Страница 17: ...P 05 P 06 P 07 P 08 P 09 10 5 7 11 12 DIY 7 7 1 P1 P12 DIY 01 01 02 03 04 05 06 07 09 10 11 12 DIY 7 2 5 8 8 1 DIY 8 2 0 24 0 00 8 3 0 24 Mon Tue Wed Thu Fri Sat Sun 8 4 COPY COPY 8 5 DIY 9 9 1 1 0 24...

Страница 18: ...0 IN TEC PS1 M 2000 IN TEC PS1 M 2500 IN 10 TEC PS1 LE 500 IN TEC PS1 LE 1000 IN TEC PS1 LE 1500 IN TEC Ps1 LE 2000 IN TEC PS1 LE 2500 IN TEC PS1 RCE 500 IN TEC PS1 RCE 1000 IN TEC PS1 RCE 1500 IN TEC...

Страница 19: ...berk RU 0001 11AB71 123308 3 1 323 115162 28 4 7 495 6044266 7 495 6044266 52161 2 30 2007 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 TCRU C IL AB71 B 00074 25 06 2012 24...

Страница 20: ...www timberk com www timberk com 39 38 Timberk Timberk www btpart ru www timberk com Timberk www timberk com Timberk c 10 www btpart ru...

Страница 21: ...www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 22: ......

Страница 23: ...www timberk com...

Отзывы: