background image

www.timberk.com • electric convector heater

www.timberk.com • electric convector heater

5

4

10.  A built-in fall sensor will switch off the convector if it is turned away 

from a vertical position, for example, if it is accidentally tipped over 

when operated on legs.

11.  Additionally, it is possible to purchase and install a set of a humidifier 

and a heated towel rail.

12. Wide variety of control panels in the series: control panel with a 

mechanical thermostat (TEC.PS1 M…IN), control panel with a high-

precision electronic thermostat and LED display (TEC.PS1 LE…IN), 

control panel with a high-precision electronic thermostat, LED display 

and remote controller (TEC.PS1 RCE…IN), as well as control panel 

with a high-precision electronic thermostat, LCD display and an 

opportunity for a weekly programming of convector operation modes 

(TEC.PS1 PGE…IN).

Dimensions of convectors depending on power (Fig. 1)

Timber series convectors are distinguished on maximum consumed power 

of the heating element and differ from each other by the unit’s length at 

equal height and depth. (Standard overall height of all units is equal to 400 

mm). This pattern in forming overall dimensions allows the consumer to 

use Timberk convectors of different power in one room next to each other 

without breaking regular symmetries, and perfectly integrating several 

units into your interior at the same time.

Overall dimensions of the convector 
Table 2

Dimensional specifications

For a detailed description of technical parameters and characteristics go to www.timberk.com 

or contact TIMBERK  official dealers.

Technical characteristics

Table 1

Fig. 1

Identification

number

Rated

voltage,

V/Hz

Rated

current, 

A

Rated

power, 

W

Power

modes, W

Class of

protection

Class of 

electric 

protection

Dimensions,

mm

Net

weight,

kg

TEC.PS1 M

500 IN

220-

240/50

2,3

500

250/500

IP24

class I

476х400х57

4,0

TEC.PS1 M

1000 IN

220-

240/50 

4,5

1000

500/1000

IP24

class I

656х400х57

5,1

TEC.PS1 M

1500 IN

220-

240/50 

6,8

1500

750/1500

IP24

class I

930х400х57

6,7

Identification

number

Rated

voltage,

V/Hz

Rated

current, 

A

Rated

power, 

W

Power

modes, W

Class of

protection

Class of 

electric 

protection

Dimensions,

mm

Net

weight,

kg

TEC.PS1 M

2000 IN

~

220-

240/50 

9,1

2000

1000/2000

IP24

class I

1267х400х57

8,6

TEC.PS1 M

2500 IN

~

220-

240/50 

11,4

2500

1250/2500

IP24

class I

1267х400х57

8,7

TEC.PS1 LE

500 IN

~

220-

240/50 

2,3

500

250/500

IP24

class I

476х400х57

4,0

TEC.PS1 LE

1000 IN

~

220-

240/50 

4,5

1000

500/1000

IP24

class I

656х400х57

5,1

TEC.PS1 LE

1500 IN

~

220-

240/50 

6,8

1500

750/1500

IP24

class I

930х400х57

6,7

TEC.PS1 LE

2000 IN

~

220-

240/50 

9,1

2000

1000/2000

IP24

class I

1267х400х57

8,6

TEC.PS1 LE

2500 IN

~

220-

240/50 

11,4

2500

1250/2500

IP24

class I

1267х400х57

8,7

TEC.PS1 PGE

500 IN

~

220-

240/50 

2,3

500

250/500

IP24

class I

476х400х57

4,0

TEC.PS1 PGE

1000 IN

~

220-

240/50 

4,5

1000

500/1000

IP24

class I

656х400х57

5,1

TEC.PS1 PGE

1500 IN

~

220-

240/50 

6,8

1500

750/1500

IP24

class I

930х400х57

6,7

TEC.PS1 PGE

2000 IN

~

220-

240/50 

9,1

2000

1000/2000

IP24

class I

1267х400х57

8,6

TEC.PS1 PGE

2500 IN

~

220-

240/50 

11,4

2500

1250/2500

IP24

class I

1267х400х57

8,7

TEC.PS1 RCE

500 IN

~

220-

240/50

2,3

500

250/500

IP24

class I

476х400х57

4,0

TEC.PS1 RCE

1000 IN

~

220-

240/50

4,5

1000

500/1000

IP24

class I

656х400х57

5,1

TEC.PS1 RCE

1500 IN

~

220-

240/50

6,8

1500

750/1500

IP24

class I

930х400х57

6,7

TEC.PS1 RCE

2000 IN

~

220-

240/50

9,1

2000

1000/2000

IP24

class I

1267х400х57

8,6

TEC.PS1 RCE

2500 IN

~

220-

240/50

11,4

2500

1250/2500

IP24

class I

1267х400х57

8,7

Series

Power modes

TL (mm)

H (mm)

A (mm)

L (mm)

B (mm)

H23 (mm)

TEC. PS1... 

2500/1250

1267

400

458

350

458

188

TEC. PS1... 

2000/1000

1267

400

458

350

458

188

TEC. PS1... 

1500/750

930

400

290

350

290

188

TEC. PS1... 

1000/500

656

400

218

250

188

188

TEC. PS1... 

500/250

476

400

194

155

128

188

IMPORTANT! 

The manufacturer reserves the right to change the set-list 

of the device (including liquid and powder components) 

for different supplies without prior notice. The changes 

either in no way influence the basic technical parameters 

of the device or may improve them, and also not violate 

the legislation or quality standards of the countries of 

manufacture, transit and selling.
The changes in the set-list may result in changing of the 

weight and dimensions of the device, but not more than 

by +\- 5-20% (depending on the product category)

500 W

476 mm

1000 W

656 mm

1500 W

930 mm

2000/2500 W

1267 mm

400 mm

Fig. 2

1. Control panel
2. Outlet grill louver
3. Unit’s case (front part)
4. Support legs
5. Cold air inlet
6. Humidifier*
7. Heated towel rail*

* optional devices, not included in the standard scope of delivery (to be purchased separately)

1. Convector, with a bracket and a carrying handle - 1 pc.
2. Mounting set - 1 pc.
3. Support leg - 2 pcs.
4. Operation manual - 1 pc.
5. Guarantee card - 1 pc.
6. Packing - 1 pc.

4. DESCRIPTION OF THE CONVECTOR (FIG. 2)

5. SCOPE OF DELIVERY

6

2

3

4

5

Fig. 3

7

1

Содержание TEC.PS1 LE 2000 IN

Страница 1: ...PGE 1500 IN TEC PS1 PGE 2000 IN TEC PS1 PGE 2500 IN TEC PS1 RCE 500 IN TEC PS1 RCE 1000 IN TEC PS1 RCE 1500 IN TEC PS1 RCE 2000 IN TEC PS1 RCE 2500 IN TEC PS1 M 500 IN TEC PS1 M 1000 IN TEC PS1 M 150...

Страница 2: ...ower cord must be repaired only in authorized service centers of the manufacturer and by skilled specialists 14 Never try to repair it on your own This may harm your health and affect the unit s guara...

Страница 3: ...57 8 7 TEC PS1 LE 500 IN 220 240 50 2 3 500 250 500 IP24 class I 476 400 57 4 0 TEC PS1 LE 1000 IN 220 240 50 4 5 1000 500 1000 IP24 class I 656 400 57 5 1 TEC PS1 LE 1500 IN 220 240 50 6 8 1500 750...

Страница 4: ...modes TEC PS1 RCE IN series convector heaters are equipped with a high precision electronic thermostat with LED display and a remote controller The unit is ready to use Connection to electric mains 1...

Страница 5: ...The convector is equipped with an air ionizer 6 1 You can switch on and off the air ionizer by means of the ionizer switch Ionizer located on the control panel 6 2 Ionizer switch illumination lights...

Страница 6: ...and will operate with the last user settings except for timer settings after power supply is restored 11 Convector switching off To switch off the convector press and hold button on the control panel...

Страница 7: ...n the comfort and economy operation modes 10 Button It is used to increase the selected value 11 Button It is used to decrease the selected value 12 programming button It is used to select preset prog...

Страница 8: ...mode enter or find a program of a day from where you want to copy your settings and select it with the use of the button When you have selected a required day press the button After that a symbol COP...

Страница 9: ...cleaned from dust and dirt For this purpose it is necessary to dismount the unit from the bracket and after cleaning it is necessary to return it to the initial position Preventive cleaning should be...

Страница 10: ...www timberk com www timberk com 19 18 imberk Timberk 220 240 1 2 3 4 5 6 7 8 1 2 9 180 10 11 12 13 14 15 16 17 18 OFF TEC PS1 M IN 19 20 21 22 23 24 25 26 27...

Страница 11: ...00 IN 220 240 50 6 8 1500 750 1500 IP24 class I 930 400 57 6 7 TEC PS1 LE 2000 IN 220 240 50 9 1 2000 1000 2000 IP24 class I 1267 400 57 8 6 TEC PS1 LE 2500 IN 220 240 50 11 4 2500 1250 2500 IP24 clas...

Страница 12: ...3 4 5 7 1 1 2 3 2 4 2 4 5 6 5 4 7 50 60 6 8 9 7 1 2 5 6 7 3 2 TL H A L B H23 TEC PS1 2500 1250 1267 400 458 350 458 188 TEC PS1 2000 1000 1267 400 458 350 458 188 TEC PS1 1500 750 930 400 290 350 290...

Страница 13: ...g 5 TEC PS1 M IN 1 POWER 2 Economy Normal 3 3 1 5 30 3 2 Heating Heating 4 5 2 3 4 5 1 220 240 2 3 4 10 2000 12 2500 50 TEC PS1 M IN TEC PS1 LE IN c LED TEC PS1 RCE IN c LED TEC PS1 PGE IN L D TEC PS1...

Страница 14: ...Timer 0 5 2 1 0 24 5 3 3 Timer TEC PS1 LE IN TEC PS1 RCE IN 1 ON Power 2 LO HI 3 3 1 5 30 1 3 2 24 17 3 3 Economy 1 2 Power 3 Normal 4 LED 5 Ionizer 6 7 LO HI 8 Economy 9 TEC PS1 LE IN TEC PS1 RCE IN...

Страница 15: ...imer 6 3 7 8 8 1 3 3 8 2 3 9 9 1 9 2 Ionizer 9 3 10 RESTART 11 3 OFF TEC PS1 RCE IN 1 ON Power POWER 24 2 MODE 3 3 1 5 30 1 3 2 24 17 3 3 SET 3 4 SET 3 5 4 4 1 SET 4 2 SET 4 3 SET 5 7 5 5 1 SET OFF 5...

Страница 16: ...7 Normal 8 L D TEC PS1 PGE IN 9 3 9 10 11 12 13 14 15 TEC PS1 PGE IN 1 ON Power 2 2 1 1 0 24 2 2 1 59 2 3 Mon Tue Wed Thu Fri Sat Sun 3 3 1 4 4 1 5 30 1 4 2 24 17 4 3 Normal 4 4 Economy 5 5 1 Normal...

Страница 17: ...P 05 P 06 P 07 P 08 P 09 10 5 7 11 12 DIY 7 7 1 P1 P12 DIY 01 01 02 03 04 05 06 07 09 10 11 12 DIY 7 2 5 8 8 1 DIY 8 2 0 24 0 00 8 3 0 24 Mon Tue Wed Thu Fri Sat Sun 8 4 COPY COPY 8 5 DIY 9 9 1 1 0 24...

Страница 18: ...0 IN TEC PS1 M 2000 IN TEC PS1 M 2500 IN 10 TEC PS1 LE 500 IN TEC PS1 LE 1000 IN TEC PS1 LE 1500 IN TEC Ps1 LE 2000 IN TEC PS1 LE 2500 IN TEC PS1 RCE 500 IN TEC PS1 RCE 1000 IN TEC PS1 RCE 1500 IN TEC...

Страница 19: ...berk RU 0001 11AB71 123308 3 1 323 115162 28 4 7 495 6044266 7 495 6044266 52161 2 30 2007 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 TCRU C IL AB71 B 00074 25 06 2012 24...

Страница 20: ...www timberk com www timberk com 39 38 Timberk Timberk www btpart ru www timberk com Timberk www timberk com Timberk c 10 www btpart ru...

Страница 21: ...www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 22: ......

Страница 23: ...www timberk com...

Отзывы: