Water heater mounting
NOTE:
Please, use accessories, provided by the manufacturer, to install the
water heater. Electric water heater must not be mounted on a wall prior
you make sure that the bracket is installed firmly and securely.
Otherwise the electric water heater may fall down from the wall, which
may cause its damage and even serious accidents involving bodily
injury. When determining points for bolt holes, it is necessary to
provision some spare space between the lower part of the water heater
and the floor, and as to the MS2/RS2 line there also must be some space
between the right side of the water heater and the wall on the right, not
less than 0.6 m to make it convenient to perform maintenance if
necessary.
Fig
.
10
1. Electric water heater should be mounted on a firm wall. If the wall is not
robust enough to hold the weight equal to the doubled weight of the
overall water heater weight, fully filled with water, then it should be
mounted on a special support.
2. After you chose the proper place to install the water heater, determine
points for holes for expansion hook bolts (to be determined in accordance
with the data sheet for the appliance you chose). Drill two holes of the
corresponding depth in the wall using a drill, dimensionally fit for expansion
bolts, enclosed with the water heater, insert bolts, turn the hook upwards,
securely tighten nuts and then hang the electric water heater on these
hooks (for RS1/RS2
/
RS7 series) (see Fig. 10a).
NOTE:
In places or on the wall, where there may be a water contact, the power
outlet installation height must be not less than 1.8 m.
Connection to water main
1. The heater must be connected to water main with at least 0.1 MPa
pressure; maximum pressure is 0.7 MPa.
NOTE:
The water heater is the appliance, operating in such a manner that
pressure of water in the water heater corresponds to the pressure of
water in water main. If pressure in the main exceeds 0.7 MPa, then it is
necessary to mount a pressure reducer before the water heater so that
pressure doesn't exceed 0.7 MPa.
To mount MS2 series water heater, fix a securing plate on a wall and hang
the water heater on it (Fig. 10 b).
3. Fix a power outlet to the wall. Requirements to the outlet are as follows:
230V/10A, single-phase, three-wired. It is recommended to place the
outlet on the right side above the water heater.
2. G1/2 diameter pipes are used to connect the water heater to the water
pipeline.
3. To prevent a leakage when connecting pipes, use rubber sealing
gaskets on the threaded pipe ends.
4. Screw a relief valve to the inlet nozzle, marked blue and embossed
arrow of the water flow direction, so that the water flow direction
coincides with direction of the arrow on the valve's case.
NOTE:
Do not mount additional accessories, such as a shut-off valve, between
the relief valve and the inlet nozzle.
Fig
.
10
b
8
www.timberk.
electrical storage water heater
com
Содержание SWH MS210H
Страница 22: ...5 6 7 1 230 2 10A 2 3 1 5 50 3 230 1 1 2 2 1 3 3 3 1 11 11 22 www timberk com ...
Страница 25: ...9 16 18 17 1 2 0ºC 3 4 5 MS2 RS2 17 RS1 RS7 18 www timberk ru Timberk 25 8 HEATING 9 Timberk www timberk com ...
Страница 26: ...7 14 50 6 RS2 16 8 11 19 2 RS7 10 6 1 2 3 Timberk Timberk Timberk Timberk Timberk Timberk 26 www timberk com ...
Страница 28: ... Timberk Timberk www btpart ru www timberk com Timberk 28 www timberk com ...
Страница 29: ...29 www timberk com RU Timberk Timberk KZ AK BY OS TJ UA KG CIS c 10 ...
Страница 31: ...www timberk com ...
Страница 32: ...www timberk com ÀÂ71 ...