e) Connection between exhaust tube and chimney must be sealed
f) There must be Inspection control hole
g) “T” Inspection tube for collecting condensate
Stove is constructed in way that it is connected to chimney with tubes of 80mm diameter.
Flexible tubes are not allowed!
All mounted tubes and their connections must be hermetic.
ONLY ONE STOVE CAN BE MOUNTED PER CHIMNEY
ONLY ONE CHIMNEY CAN BE CONNECTED TO THE STOVE
The f is constructed in such a way that it is connected to the chimney with 80 mm diameter
flue pipes. Flexible hoses for connecting the stove to the chimney are not allowed. Installation of flue
pipes from the furnace to the chimney should be done in such a way that they are hermetically. The
stove must be installed only on one chimney (external or internal) and only one stove can be installed
on one chimney.
It is not permissible for the gases to run through the wall only through a horizontal pipe (see
figure below), due to possible disturbances to the operation of the furnace in the case of wind. In this
case, inform the user of the stove that it is obliged to install the vertical part of the flue pipe (insulted,
with double wall) with the obligatory cap on the top of the stove (wind protection).
Flue gasses outlet.: unsatisfactory / satisfactory