TS4-F/TS4-R-F:
·
Output voltage without active transmitter signal is
0.6V
·
Output voltage with active transmitter signal will be normal
module V
MP
or V
OC
·
If output is 0V contact Tigo support
Check that the system conforms to the design rules
for TS4-F:
·
Up to 10 strings per RSS Core (CT)
·
Up to 30 modules per string
·
String length up to 1000ft (
total
cable length from
+
to
-
)
·
Homeruns through RSS Core must be the same polarity
(all positive
or
all negative)
RSS Transmitter:
·
Power LED should be lit and Signal LED should be blinking
during operation
·
Verify that RSS Core wiring is correct
·
Power cycle RSS Transmitter if Signal LED is unlit
·
While RSS Transmitter is powered off, string voltage should be
(0.6V * number of modules)
·
While RSS Transmitter is powered on, full string voltage should
be present
Test individual strings with active RSS Transmitter
one at a time in case of unexpected voltage.
Troubleshooting TS4-F and RSS Transmitter