@TI-02 USER MANUAL
10
OL
– Overload
ST
– Stable
NT
– Net weight
US
– Unstable
GS
– Gross weight
Fixed 18 BYTES ASCII (kg g t lb)
1
2
1
1
2
1
1
2
3
4
5
6
7
8
1
2
1
2
HEAD1
,
HEAD2
,
DATA
UNIT CR LF
Fixed 21 BYTES ASCII (tl.T lboz)
1 2 1 1 2 1 1 2 3 4 5 6 7 8 9 1 2 3 4 1 2
HEAD1
,
HEAD2
,
DATA
UNIT
CR LF
Fixed 19 BYTES ASCII (pcs)
1
2
1
1
2
1
1
2
3
4
5
6
7
8
1
2
3
1
2
HEAD1
,
HEAD2
,
DATA
UNIT
CR LF
UF-7
Speed setting
(
*
)
Modes:
spEED1
: Standard speed
spEED2
: High speed
spEED3
: Low speed
1. Press the key to enter.
2. Press the key to select the desired mode.
3. Press the key to confirm.
UF-8
Zero tracking
(
*
)
Modes:
Zp 0
: OFF
Zp 1
: One division tracking at zero
Zp 2
: Two division tracking at zero
Zp 3
: Three division tracking at zero
Zp 4
: Four division tracking at zero
Zp 5
: Five division tracking at zero
1. Press the key to enter.
2. Press the key to select the desired mode.