14 | Automate
™
Programming Instructions | Flush Wall Switch
9
TROUBLE SHOOTING
Problem
Cause
Remedy
Switch battery is discharged
Replace battery
Motor is not responding
Battery is inserted incorrectly
Check battery polarity
Radio interference / Shielding
Ensure remote is positioned away
from metal objects and that aerial on
motor or receiver is kept straight and
away from metal.
Receiver distance is too far
from remote
Move remote to a closer position or
consider a repeater for improved
performance.
Power failure
Check power supply to motor is
connected and active.
Incorrect motor wiring
Check wiring is connected correctly
(refer to motor installation
instructions).
Cannot set limits on a single
motor (multiple motors
respond)
Using channel 0 to adjust
motor limits
(Multi channel remote ONLY)
Always reserve an individual channel
for programming functions.
SYSTEM BEST PRACTICE - Provide
an extra 15 channel remote in your
multi motor projects, that provides
individual control for each motor for
programming purposes.
Motor will not go down after
setting the top limit.
Top limit was set using the
DOWN and STOP buttons.
Reset the motor and begin
programming sequence again.
Remember that upper limit is to be
set using the
UP and STOP buttons,
and the down limit is set using the
DOWN and STOP buttons.
Motor will pair, but can not set
limits.
Switch is in a locked state.
Control must be unlocked
to set limits or perform any
multi-button functions.
Press and hold
STOP button for 15
seconds, until locked state changes.
TIGER WINDOW FASHIONS