TIF8800, 8800A, 8850
Combustible Gas Detectors
9
LEAK DETECTION
>
Rugged custom carrying case
>
Made in the USA
Applications and Uses:
>
Gas lines and Pipes
>
Exhaust and Fuel leaks
>
Propane filling stations
>
Fuel in marine bilges
>
Heat Exchanger leaks
>
Check manholes for safety
>
Detect arson residue
>
IAQ tests
>
Liquid or gas fired heating systems
>
Detects
dangerous
explosive gases
>
Used in almost any situation where combustible
gasses, vapor or residues need to be found
>
Applications include: Gas lines and pipes, aids in
identifying Heat Exchanger leaks and hazardous
living/working environments (Note:
NOT
an effective
Carbon Monoxide detector – see TIF-8500A,
page 47)
>
Instantaneous response
>
15" Flexible stainless steel probe
>
Automatic warm up
>
Ultimate sensitivity as low as 1 ppm (gasoline)
>
Adjustable sensitivity
>
Audible “Geiger counter” type signal
>
UL, CE and MSHA approved
TIF 8850
TIF 8800
TIF 8800A
C
Partial List of Detectable Compounds
Compound
Min. detectable
concentration
Acetylene
50 ppm
Iso-Butane (R600a) 500 ppm
Methane
500 ppm
Ethane (R170)
500 ppm
Propane (R290)
500 ppm
Ethylene
500 ppm
Hydrogen
500 ppm
Methyl Ether
500 ppm
Vinyl Chloride
5 ppm
Compound
Min. detectable
concentration
Methyl Chloride
5 ppm
Hydrogen Sulfide
5 ppm
Acetone
50 ppm
Methanol
50 ppm
Ammonia (R717)
20 ppm
Gasoline
1 ppm
Chlorine
1 ppm
Features
TIF8800
TIF8800A
TIF8850
TIF8800INTL
TIF8800AINTL
TIF8850I
Battery Charger
115V
115V
115V
220V
220V
220V
LED Leak Sensitivity
Lights
6 Lights
6 Lights
6 Lights
6 Lights
Audio Mute button to
silence alarm
Yes
Yes
Probe Length
15” (38cm)
Power Supply
(Two) 2.4V Ni-Cad Batteries
Battery Life
4 Hours/Charge
Operating Temp
32º F to 125º F (0º C to 52º C)
Optional Accessories
Part Number
Cigarette lighter charger TIF8805
Replacement Parts
Part Number
Sensor
TIF8801
Rechargeable Ni-Cad batteries (2 each) TIF8806A
115V battery charger
TIF8803A
220V battery charger
TIF8806B
Carrying Case
TIF549
Battery Cover
A10015RR