Troubleshooting
79
MOD.x LO Lock
MOD.x Local Oscill Unlocked
Modulator Loss of Local
Oscillator Lock
Verify connections.
Set modulator input to backplane.
Ensure Mux rate = the Modulator rate.
MOD.x No Mux
MOD.x No Local Input Source Modulator is not receiving the
transport stream.
Verify connections.
Set modulator input to backplane.
Ensure Mux rate = the Modulator rate.
MOD.x SC Lock
MOD.x Symbol Clock Unlock
Modulator Loss of Symbol Clock
Lock
Verify connections.
Set modulator input to backplane.
Ensure Mux rate = the Modulator rate.
MUX.x CPO Ovfl
MUX.x CPO Out Overflw
TTX CPO Overflow
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x CPO Sync
MUX.x CPO Sync Loss
TTX CPO Sync Loss
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x CPO Underflow
MUX.x CPO Output Underflow TTX CPO Underflow
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x EPO Ovfl
MUX.x EPO Out Ovrflw
TTX EPO Overflow
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x EPO Sync
MUX.x EPO Sync Loss
TTX EPO Sync Loss
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x EPO Underflow
MUX.x Ext Output Underflow
TTX EPO Underflow
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x Ext Input
MUX.x Ext Input Loss
TTX External Input Loss
Verify input connections.
Verify external transport stream.
Ensure input source is in proper format and conforms to
specified input levels.
MUX.x Ext Sync Loss
MUX.x Ext Inp Sync Err
TTX External Input Sync Loss
Occurs when configuring stack
and unit encounters momentary
loss of signal.
If unit is functioning normally, clear faults and continue
operations.
If unit continues to log this as a current fault, reset unit.
MUX.x Ext Tab
MUX.x Ext Table Ovrfl
TTX ECPI Overflow
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x Init
MUX.x Init Error
Mux Initialization Error
Power cycle the unit.
If normal operations do not resume, contact Tiernan
Customer Service.
MUX.x LCPI Tab
MUX.x Loc Table Overfl
TTX LCPI Overflow
Verify internal and external MUX rates.
Verify MCPC stack configuration. Ensure encoder MUX
rates are in sync.
MUX.x Loc Input
MUX.x Loc Input Loss
TTX Local Input Loss
If current fault, reset unit. If unit continues to fail, contact
Tiernan Customer Service.
If in fault history log, clear faults and continue operations.
MUX.x Loc PAT
MUX.x Loc PAT Timeout
TTX Local PAT (program
association table) Timeout
Occurs on power-up.
If unit is functioning normally, clear faults and continue
operations.
If unit continues to log this as a current fault, reset unit.
MUX.x Loc Sync
MUX.x Loc Input Sync
TTX Local Input Sync Loss
Occurs when configuring stack
and unit encounters momentary
loss of signal.
If unit is functioning normally, clear faults and continue
operations.
If unit continues to log this as a current fault, reset unit.
TE3000 Fault Summary (continued)
Front Panel Display
Remote Unit Display
Description
Action Required
Содержание TE3000
Страница 10: ...viii Preface ...
Страница 14: ...4 TE3000 Overview ...
Страница 52: ...42 Using the Front Panel ...
Страница 94: ...84 Maintenance and Software Upgrades ...
Страница 96: ...86 Technical Specifications ...
Страница 102: ...92 TE3000 PID Assignments ...
Страница 112: ...102 Glossary ...