58
Using a Remote Unit
MUX RED_STATE
2
Standby, Armed,
Triggered
Standby
Sets the operating state of the spare encoder in a redundant system.
Parameters are:
!
Standby = spare encoder is in an inactive state and will not begin
operations in the event of a primary encoder failure
!
Armed = sets the spare encoder to begin operations in the event
that a primary encoder fails
!
Triggered = this state cannot be set; it is entered into automatically,
from the Armed state, when the loss of an external service is
detected.
Front panel command equivalent: Config>Tx Strm>Redund State
MUX RSR
2
—
—
Displays the name of the external service that has been replaced by
the redundant unit. Valid only in TRIGGERED state.
3
Front panel command equivalent: none
MUX SMPTE_EN
On, Off
Off
Setting determines whether or not the SMPTE output is included in the
transport stream.
Front panel command equivalent: none
TAB ATSC_NAME
<string>
—
Sets the ATSC name; up to 8 characters may be used.
Front panel command equivalent: none
TAB AUD_A_PID <#>
where # is a valid PIDs
0
Sets the Audio A PID to be included in the output transport stream.
Zero is the default PID.
Front panel command equivalent: none
TAB AUD_B_PID <#>
where # is a valid PIDs
0
Sets the Audio B PID to be included in the output transport stream.
Zero is the default PID.
Front panel command equivalent: none
TAB CARRIER_HZ
0-4294967295
in Hz
566310000 Hz Sets the carrier frequency when ATSC table types are enabled.
Front panel command equivalent: none
TAB MINORCH
1 to 99
2
Sets the minor channel in the ATSC tables.
Front panel command equivalent: Config>Service>Setup>Minor
Channel
TAB MAJORCH
1 to 99
30
Sets the major channel in the ATSC tables.
Front panel command equivalent: Config>Service>Setup>Major
Channel
TAB NIT_CC
1/1, 1/2, 2/3, 3/4, 5/6,
7/8
5/6
Sets the current FEC Convolution Code Rate entered in the NIT.
Front panel command equivalent: none
TAB NIT_MOD
QPSK
—
Sets the NIT modulation type.
Front panel command equivalent: none
TAB NIT_NAME
<string>
MPEG-2
Encoder
Used to enter the network name; up to 115 characters may be used.
Front panel command equivalent: none
TAB NIT_NETID
0 to 65535 (decimal)
0 (zero)
Used to enter the Network ID in the NIT.
Front panel command equivalent: none
TAB NIT_POL
Hor, Vert, Left, Right
Ver
Sets the transmitted signal polarization. Parameters are:
!
Hor =linear-horizontal polarization
!
Ver = linear- vertical polarization
!
Left = circular-left polarization
!
Right = circular-right polarization
Front panel command equivalent: none
TAB NIT_SR ###.#####
###.#####
—
Sets the NIT transmitted symbol rate in sps.
Front panel command equivalent: none
TAB NIT_WSTFLG
East, West
West
Sets the satellite orbital position. Parameters are:
!
East = satellite orbital position is East
!
West = satellite orbital position is West.
Front panel command equivalent: none
TE3000 Remote Command Descriptions
(continued)
Remote Command
Parameter Range
Factory
Default
Description
Содержание TE3000
Страница 10: ...viii Preface ...
Страница 14: ...4 TE3000 Overview ...
Страница 52: ...42 Using the Front Panel ...
Страница 94: ...84 Maintenance and Software Upgrades ...
Страница 96: ...86 Technical Specifications ...
Страница 102: ...92 TE3000 PID Assignments ...
Страница 112: ...102 Glossary ...