WAVEJET™ SL
MICROWAVE OVEN
COMPONENT MAINTENANCE MANUAL
WITH ILLUSTRATED PARTS LIST
25-30-51
Page 3003
December 1, 2003
(7) Remove carriage link (135) from latch (130) by removing screw (140),
flatwasher (145), and lockwasher (150).
(8) Remove latching mounting bracket (160) by removing three screws (165).
Operate paddle and remove latch through the front of the opening.
SUBTASK 25-30-51-00-004-A01
D.
Component Tray and Magnetron Removal (IPL, Figure 10001)
(1) Remove bottom cover (170) by removing three screws (175) in the front
through the access holes provided. Across the back and sides, remove nine
screws (180).
(2) Remove microwave mounting brackets (185) by removing two each of screws
(190), screws (195) and flatwashers (200).
(3) Remove the component tray assembly (205) by removing four screws (210)
at the rear of the assembly and two screws (215) and two spacers (220) at
the front of the component tray assembly.
(4) Remove the wire clamp (225) from the wiring harness by removing screw
(230), flatwasher (235) and nut (240).
(5) Where necessary to remove the component tray assembly, disconnect wiring
at terminal board locations carefully noting locations for reassembly.
(6) Slide the component tray assembly (205) out the side of the microwave.
(7) Remove the magnetron thermostat (250) by removing two screws (255).
Wipe the thermal grease (260) from the thermostat.
(8) Remove the magnetron (265) by removing three each of screw (270),
flatwasher (275) and nut (280). Discard the magnetron (265).
CAUTION:
Once a magnetron is removed from the microwave, the magnetron
cannot be reused. The gasket is permanently attached and is
designed for 1 use only. Discard the magnetron once it is removed.