background image

22

NVA100X - Getting started - 01 - 2018

SET

NV

A100X_menuset2.ai

PROCEED SET MENU’

PROFILE A

PROCEED PROFILE A MENU’

FROM PROFILE A MENU’

27V1

U1<def enable  OFF

 

0.5 En

tU1<def 

1 s

U1<BLK1 OFF

U1<BF 

OFF

Relays U1<

U1<ST-K 

-

U1<TR-K 

-

LEDs U1<

U1<ST-L 

-

U1<TR-L 

-

P1>DIR   P Forward

P1>RES      0.00 s

P1>def enable  OFF

P1>def     0.50 Pn

tP1>def     1.00 s

P1>BLK1        OFF

P1>BF          OFF

Relays P1>

P1>ST-K          -

P1>TR-K          -

LEDs P1>

P1>ST-L          -

P1>TR-L          -

P2>DIR   P Forward

P2>RES      0.00 s

P2>def enable  OFF

P2>def     0.50 Pn

tP2>def     1.00 s

P2>BLK1        OFF

P2>BF          OFF

Relays P2>

P2>ST-K          -

P2>TR-K          -

LEDs P2>

P2>ST-L          -

P2>TR-L          -

27V1  

>>

U1< Element 

>>

32P  

>>

P1> Element 

>>

P2> Element 

>>

Q1>DIR   Q Forward

Q1>RES      0.00 s

Q1>def enable  OFF

Q1>def     0.50 Qn

tQ1>def     1.00 s

Q1>BLK1        OFF

Q1>BF          OFF

Relays Q1>

Q1>ST-K          -

Q1>TR-K          -

LEDs Q1>

Q1>ST-L          -

Q1>TR-L          -

Q2>DIR   Q Forward

Q2>RES      0.00 s

Q2>def enable  OFF

Q2>def     0.50 Qn

tQ2>def     1.00 s

Q2>BLK1        OFF

Q2>BF          OFF

Relays Q2>

Q2>ST-K          -

Q2>TR-K          -

LEDs Q2>

Q2>ST-L          -

Q2>TR-L          -

32Q  

>>

Q1> Element 

>>

Q2> Element 

>>

Logic37 OR

I<def 

OFF

 

0.5 In

t<def      

1 s

I<BLK1         OFF

I<BF           OFF

Relays I<

I<ST-K          -

I<TR-K          -

LEDs I<

I<ST-L          -

I<TR-L            -

37  

>>

I< Element 

>>

P1<DIR   P Forward

P1<RES      0.00 s

P1<def enable  OFF

P1<def     0.50 Pn

tP1<def     1.00 s

P1<BLK1        OFF

Relays P1<

P1<ST-K 

      -

P1<TR-K 

      -

LEDs P1<

P1<ST-L 

      -

P1<TR-L 

      -

P2<DIR   P Forward

P2<RES      0.00 s

P2<def enable  OFF

P2<def     0.50 Pn

tP2<def     1.00 s

P2<BLK1        OFF

Relays P2<

P2<ST-K 

      -

P2<TR-K 

      -

LEDs P2<

P2<ST-L 

      -

P2<TR-L 

      -

37P 

>>

CB-37P Enable  OFF

tARM-P< 

1.00 s

Common 

>>

P1< Element 

>>

P2< Element 

>>

Q1<DIR   Q Forward

Q1<RES      0.00 s

Q1<def enable  OFF

Q1<def     0.50 Qn

tQ1<def     1.00 s

Q1<BLK1        OFF

Relays Q1<

Q1<ST-K 

      -

Q1<TR-K 

      -

LEDs Q1<

Q1<ST-L 

      -

Q1<TR-L 

      -

Q2<DIR   Q Forward

Q2<RES      0.00 s

Q2<def enable  OFF

P2<def     0.50 Qn

tQ2<def     1.00 s

P2<BLK1        OFF

Relays Q2<

Q2<ST-K 

      -

Q2<TR-K 

      -

LEDs Q2<

Q2<ST-L 

      -

Q2<TR-L 

      -

CB-37Q Enable  OFF

tARM-Q< 

1.00 s

37Q 

>>

Common 

>>

Q1< Element 

>>

Q2< Element 

>>

40AL Enable 

OFF

Alpha40AL 

45 gr.

t40AL 

1.00 s

40ALBLK1       OFF

Relays 40AL

40ALST-K 

      -

40ALTR-K 

      -

LEDs 40AL

40ALST-L 

      -

40ALTR-L 

      -

XC1XD1 Enable  OFF

XC1 

1.00 Znf

XD1 

1.00 Znf

tXC1XD1 

1.00 s

tXC1XD1-RES  0.0 s

XC1XD1-BLK1 OFF

40ALdisbyXC1XD1 OFF

XC1XD1-BF OFF

Relays XC1XD1

XC1XD1ST-K       -

XC1XD1TR-K       -

LEDs XC1XD1

XC1XD1ST-L       -

XC1XD1TR-L       -

XC1XD1 Enable  OFF

XC1 

1.00 Znf

XD1 

1.00 Znf

tXC1XD1 

1.00 s

tXC1XD1-RES  0.0 s

XC1XD1-BLK1 OFF

40ALdisbyXC1XD1 OFF

XC1XD1-BF OFF

Relays XC1XD1

XC1XD1ST-K       -

XC1XD1TR-K       -

LEDs XC1XD1

XC1XD1ST-L       -

XC1XD1TR-L       -

Mode 40  Generator

USUP< Enable   OFF

USUP< 

0.50 Un

40 

>>

Common 

>>

40AL Element 

>>

XC1XD1 Element 

>>

XC2XD2 Element 

>>

46LT 

>>

I2> Element 

>>

Q2< Element 

>>

46M  

>>

I2> Element 

>>

I2> Element 

>>

I2>> Enable  

OFF

I2CLP> Mode 

OFF

t2CLP>> 

0.1 s

t2>>RES 

0 s

I2>>def OFF

 

1 In

I2CLP>>def 

2 In

t2>>def 

1 s

I2>>BLK1 OFF

I2>>BLK2IN OFF

I2>>BLK2OUT OFF

I2>>2ndh-REST OFF

I2>>BF OFF

I2>disbyI2>> OFF

Relays I2>>

I2>>ST-K 

      -

I2>>TR-K 

      -

LEDs I2>>

I2>>ST-L 

      -

I2>>TR-L 

      -

I2> Enable  

OFF

Type Characteristic

I2Curve

          DEFINITE

I2CLP> Mode 

OFF

t2CLP> 

0.1 s

t2>RES 

0 s

I2>def OFF

 

1 In

t2>def 

1 s

I2>inv OFF

 

2 In

t2>inv 

10 s

I2>BLK1 OFF

I2>BLK2IN OFF

I2>BLK2OUT OFF

I2>2ndh-REST OFF

I2>BF 

OFF

Relays I2>

I2>ST-K 

      -

I2>TR-K 

      -

LEDs I2>

I2>ST-L 

      -

I2>TR-L 

      -

(the same as for 46LT)

Содержание NVA100X

Страница 1: ...ing function please contact THYTRONIC TABLE OF CONTENTS Packaging 1 Contents 1 Technical support 1 INSTALLATION 2 Mounting 2 Flush mounting 2 I O diagram 4 Electrical connections 5 Output relays 6 Bin...

Страница 2: ...ns indicated in the overall dimensions drawing increased by 3 mm to ensure an adequate tolerance and gasket space between adjacent relays The depth dimension as indicated in the drawing must be increa...

Страница 3: ...started 01 2018 Remove the two vertical frames for access the holes for the fi xing screws the frames are snapped Insert the device into the slot Fit the device to the panel with four screws Replace t...

Страница 4: ...2 18 20 19 9 10 11 12 13 14 OC1E KC1 1 4 6 5 KC1 2 7 8 KC1 3 KC1 4 KC1 5 KC1 6 15 17 16 KC1 7 KC1 8 1 3 2 18 20 19 9 10 11 12 13 14 OC2F KC2 1 4 6 5 KC2 2 7 8 KC2 3 KC2 4 KC2 5 KC2 6 15 17 16 KC2 7 K...

Страница 5: ...r checks on the amperometric circuits is essential to provide appropriate support to achieve the secondary circuit shorting For security reasons it is advisable to operate in the absence of line curre...

Страница 6: ...1 5 mm2 for two conductors with same cross section Tightening torque 0 5 0 6 Nm Stripping length 10 mm Output relays The device may be confi gured with Two boards with eight command relays KC1 1 KC1 8...

Страница 7: ...ed by means ThySetter sw and local connection Set the IP address Host IP address and IP net mask n order that the NVA100X and PC parame ters are matched Set to OFF parameters Autonegotiation on relay...

Страница 8: ...le end It is recommended to terminate the line at the extremities of the same this must be performed on the RS485 line control unit and on the ProNext device placed at the furthest point serial1 sch a...

Страница 9: ...Press the key ENTER PASSWORD message is displayed followed by Password not ok press the key you can enter the personal password with the usual procedure de fault password is 0000 Press the Enter butt...

Страница 10: ...ameter from MMI can be changed and the changes can only be made by ThySetter To enable modification from MMI without password is needed to disable password lock connecting a PC with Thysetter setting...

Страница 11: ...possible faults blink lighted The display backlight is automatically activated when any key switch is set By means of the Up or Down buttons it is possible to cyclically browse through the menu option...

Страница 12: ...ower supply to the relay As example to set the operating mode of the KC1 1 output relay as ENERGIZED LATCHED the following procedure must be issued Select menu Set SET by mean of the button Down Press...

Страница 13: ...in menu till the RS485 Protocol Ethernet Local Parameters or Ethernet Remote Parameters to enter you must press the Right button As example to select the address 12 for the ModBus protocol the followi...

Страница 14: ...n 0 000 In IL 0 000 In ULmax 0 000 En UL 0 000 Un U 0 000 Un PhiL1 0 deg PhiL2 0 deg PhiL3 0 deg Alpha1 0 deg Alpha2 0 deg Alpha3 0 deg PhiE 0 deg PhiEC 0 deg DTheta 0 DThetaB I1 0 000 In I2 0 000 In...

Страница 15: ...BLK2IN DThAL2 OFF BLK2IN DThAL2 OFF BLK4IN DThAL2 OFF Trip DTh OFF BLK1 DTh OFF BLK2IN DTh OFF BLK4IN DTh OFF CLP DTh OFF 49LT 79 ActiveMode 79 OFF Run 79 OFF CycleState 79 Rest Residual time 79 0 s L...

Страница 16: ...K4IN IPD OFF Start IPD OFF Trip IPD OFF CLP IPD OFF BLK1 IPD OFF BLK2IN IPD OFF BLK4IN IPD OFF Start IPD OFF Trip IPD OFF CLP IPD OFF BLK1 IPD OFF BLK2IN IPD OFF BLK4IN IPD OFF 67 Start U OFF Trip U O...

Страница 17: ...000 Un U12r 0 000 Un U23r 0 000 Un U31r 0 000 Un IEr 0 000 IEn IECr 0 000 IEn UEr 0 000 UEn UECr 0 000 UECn PhiL1r 0 deg PhiL2r 0 deg PhiL3r 0 deg Alpha1r 0 deg Alpha2r 0 deg Alpha3r 0 deg PhiEr 0 deg...

Страница 18: ...D cnt 0 ParBk1IPD cnt 0 ParBk2IPD cnt 0 ParStIED cnt 0 ParTrIED cnt 0 ParBk1IED cnt 0 ParBk2IED cnt 0 ParStIED cnt 0 ParTrIED cnt 0 ParBk1IED cnt 0 ParBk2IED cnt 0 ParStIED cnt 0 ParTrIED cnt 0 ParBk1...

Страница 19: ...otBk2IPD cnt 0 TotStIPD cnt 0 TotTrIPD cnt 0 TotBk1IPD cnt 0 TotBk2IPD cnt 0 TotStIED cnt 0 TotTrIED cnt 0 TotBk1IED cnt 0 TotBk2IED cnt 0 TotStIED cnt 0 TotTrIED cnt 0 TotBk1IED cnt 0 TotBk2IED cnt 0...

Страница 20: ...16 IN2 1 0000000000000000 Relays KC1 8 KC1 1 00000000 Relays KC2 8 KC2 1 00000000 Fault x Cause No faults Operating phase Date Time IL1r 0 000 In IL2r 0 000 In IL3r 0 000 In UL1r 0 000 En UL2r 0 000 E...

Страница 21: ...tOFF 0 s IN1 2 matching None Logic Active ON ON Delay IN1 2 tON 0 s OFF Delay IN1 2 tOFF 0 s IN1 2 matching None ENABLE VECTOR JUMP Endphi ON 0 2 En tEndphi 0 5 s INPUTS IN1 1 IN1 16 Binary input IN1...

Страница 22: ...Common P1 Element P2 Element Q1 DIR Q Forward Q1 RES 0 00 s Q1 def enable OFF Q1 def 0 50 Qn tQ1 def 1 00 s Q1 BLK1 OFF Relays Q1 Q1 ST K Q1 TR K LEDs Q1 Q1 ST L Q1 TR L Q2 DIR Q Forward Q2 RES 0 00 s...

Страница 23: ...BLK4 OFF Dth BF OFF Dth disby50 51 OFF Relays Dth Dth K LEDs Dth Dth L Dth Element 49MG Common DthIN 0 0 DThetaB KST 2 0 K2 0 T 10 min T 1 0 T DthCLP Mode OFF tDthCLP 0 10 s DthAL1 Element DthAL1 Ena...

Страница 24: ...ILR inv 0 8 IB I MOT ST 1 IB tLR inv 10 s ILR BLK1 OFF ILR BLK2IN OFF ILR BLK2OUT OFF ILR BF OFF Relays ILR ILR ST K ILR TR K LEDs ILR ILR ST L ILR TR L ILR Enable OFF Mode51LR No speed crt1 tLRCLP 0...

Страница 25: ...U U ST K U TR K LEDs U U ST L U TR L U def Enable OFF U def 1 Un tU def 1 s U BLK1 OFF U disbyU OFF U BF OFF Relays U U ST K U TR K LEDs U U ST L U TR L Utype59 Uph ph Logic59 OR U Element U Element...

Страница 26: ...IEDCLP def 1 IEn tED def 1 s IED BLK1 OFF IED BLK2IN OFF IED BLK2OUT OFF IED BLK4 OFF IED BF OFF IED disIED OFF IED disIED OFF IED disIED OFF Relays IED IED ST K IED TR K LEDs IED IED ST L IED TR L IE...

Страница 27: ...LEDs BLOCK2IN tB L BLOCK2 INPUT ModeBLOUT1 OFF tF IPh 1 s tF IE 1 s tF IPh IE 1 s Relays BLOCK2OUT BLOCK2OUT IPh K BLOCK2OUT IE K BLOCK2OUT IPh IE K LEDs BLOCK2OUT BLOCK2OUT IPh L BLOCK2OUT IE L BLOC...

Страница 28: ...Protocol MODBUS Address 1 9600 bauds REMOTE TRIPPING PulseBLOUT1 OFF PulseBLIN1 OFF Relays PulseBLIN1 K LEDs PulseBLIN1 L PILOTE WIRE DIAGNOSTIC Test state OFF Stop test Yes Start test Yes Test KC1 1...

Отзывы: