Страница 1: ...uy your excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing R...

Страница 2: ...VD84M VD84MIR Kompakt Vakuummeter Compact Vacuummeter Betriebsanleitung Operating Instructions...

Страница 3: ...9 4 4 Druckmessung mit Datenspeicherung 11 5 Konfiguration 12 5 1 Speicherrate 12 5 2 Datenspeicher auslesen 12 5 3 Infrarotschnittstelle 13 5 4 Memoryfunktion 14 5 5 Nachjustieren 15 5 6 Anzeige Einh...

Страница 4: ...Reaktionen zwischen Werkstoffen und Prozessmedien Ber cksichtigen Sie m gliche Reaktionen der Prozessmedien infolge der Eigenerw rmung des Produkts Ger t nicht eigenm chtig umbauen oder ver ndern Info...

Страница 5: ...s Zubeh r Schutzkoffer AVD8CASE Steckernetzteil 12V AVD8N2 AlMn Batterieblock 9V AVD8ALK Spezielles Zubeh r f VD84MIR IR Adapter f PC Schnittstelle RS232 AVD8IRA Windows Software VacuGraph AVGR 2 3 Pr...

Страница 6: ...h machen Im Bereich oberhalb 20mbar und unterhalb 10 2 mbar ist die Messgenauigkeit reduziert Nach dem Anschlie en eines neuen Sensorkopfes sollte das Ger t nachjustiert werden damit wieder die volle...

Страница 7: ...und Schutz vor Besch digung Staubschutzkappe entfernen wird bei Instandhaltungsarbeiten wieder ben tigt Vakuumanschluss ber Kleinflansch DN16 ISO KF oder 1 8NPT Gewinde herstellen Bei Kleinflansch Ans...

Страница 8: ...rie am Kabelstecker anschlie en Den Batteriefachdeckel dann von unten wieder einschieben bis er einrastet Batterietypen 9V AlMn Blockbatterie Typ 6LR 61 Betriebsdauer max 40h 9V Lithium Blockbatterie...

Страница 9: ...le Batterie wechseln Druckanzeige Refresh 1 6s 100 0 001 mbar ur 0 001 mbar Ma einheit Mode Taste Mode Taste Batteriefach Deckel Anschluss f Netzadapter 12V 50mA 3 5mm Chinch Aufstellclip Sensorstecke...

Страница 10: ...en Takt Das Ger t bleibt im Cont Modus kontinuierlich in Betrieb bis es von Hand ausgeschaltet wird oder nach Ablauf der Maximal Betriebszeit automatisch abschaltet Zum Einstellen der Maximal Betriebs...

Страница 11: ...befindet sich im Memory Modus d h es speichert ab sofort neu erfasste Extremwerte bei gleichzeitig aktivierter Datenspeicherung werden dar berhinaus Messwerte entsprechend der eingestellten Speicherr...

Страница 12: ...gende Druck Der Datenspeicher ist gel scht und neue Messwerte werden entsprechend der eingestellten Speicherrate im Datenspeicher abgelegt Hierf r wird ein batterieunabh ngiger Speicherbaustein verwen...

Страница 13: ...alogging Bei off ist die interne Datenspeicherung ausgeschaltet Die Speicherrate kann nun mit der Mode Taste verstellt werden 1 6s 16s 64s 10min und off Achtung Eine nderung der Einstellung Speicherra...

Страница 14: ...bertragungsmodus daher ab sobald er nicht mehr ben tigt wird 5 3 Infrarotschnittstelle Die Infrarot Schnittstelle des VD84MIR kann zur kontinuierlichen bertragung von Messwerten an einen PC genutzt we...

Страница 15: ...ie den bertragungsmodus daher ab sobald er nicht mehr ben tigt wird Bei l ngerem Einsatz empfehlen wir alternativ statt der Batterie ein externes Steckernetzteil zu verwenden Zubeh r AVD8N2 5 4 Memory...

Страница 16: ...urationsmodus Dazu bei ausgeschaltetem Ger t Mode Taste gedr ckt halten bis die Anzeige rAtE erscheint Mode Taste nun mehrmals dr cken bis die Anzeige CAL erscheint Abgleich Atmosph rendruck Nach weit...

Страница 17: ...hjustieren des Nullpunkts ist nur m glich wenn der vom Ger t angezeigte Druck kleiner als ca 4x10 2 mbar ist Anderenfalls erscheint die Fehlermeldung Err 5 6 Anzeige Einheit Um die Anzeige Einheit ein...

Страница 18: ...edem Fall automatisch abschaltet das VD84 in den Konfigurationsmodus schalten Dazu bei ausge schaltetem Ger t Mode Taste gedr ckt halten bis die Anzeige rAtE erscheint Mode Taste nun mehrmals dr cken...

Страница 19: ...igen Reparatur vorgesehen Fehlfunktionen des Ger tes die auf Verschmutzung oder Wendelbruch zur ckzuf hren sind fallen nicht unter die Garantie Batterie Akku Betrieb Schwache Batterieleistung wird dur...

Страница 20: ...Anzeige ur Messbereich unterschritten Druck 10 3 mbar Fehlermeldung Err Justierung bei falschem Druck durchgef hrt Messwertabweichung ber steigt den Justierbereich Anzeigedruck muss bei Atmosph renabg...

Страница 21: ...Einstellzeit 400ms Betriebs temperatur 5 50 o C Lagertemperatur 20 60 o C Spannungs versorgung 9V Batterie Akku oder 12V Steckernetzteil Mini Klinke Pluspol an Spitze Leistungs aufnahme ca 110mW geta...

Страница 22: ...21 Konformit tserkl rung...

Страница 23: ...yfunction 29 4 4 Pressure Display with Datalogging 31 5 Configuration 32 5 1 Logging Rate 32 5 2 Read Out Data Memory 32 5 3 Infrared Interface 33 5 4 Memory Function 34 5 5 Adjustment 35 5 6 Pressure...

Страница 24: ...reactions between materials and process media Consider possible reactions of the process media due to the heat generated by the product Do not carry out any unauthorized conversions or modifications...

Страница 25: ...g instructions Available Accessories Protective case AVD8CASE External plug in power supply 12V AVD8N2 AlMn block battery 9V AVD8ALK Special accessories f VD84MIR IR adapter f PC interface RS232 AVD8I...

Страница 26: ...geing or extreme climatic conditions the need for readjustment may arise Accuracy is reduced in the range above 20mbar and below 10 2 mbar After a new sensor head is connected we recommend to readjust...

Страница 27: ...anliness and damage prevention when using vacuum components Remove the protective cover is required again during maintenance work Make vacuum connection via small flange DN16 ISO KF or 1 8NPT thread F...

Страница 28: ...ble plug and close the cover again by pushing it upwards until it snaps into position Battery types 9V AlMn block battery type 6LR 61 lifetime max 40h 9V Lithium block battery lifetime max 100h Operat...

Страница 29: ...e Renew battery Pressure display Refresh 1 6s 100 0 001 mbar ur 0 001 mbar Pressure Unit Mode Taste Mode Key Cover of Battery Compartment Connection f Mains Adapter 12V 50mA 3 5mm Chinch Stand Sensor...

Страница 30: ...Cont Mode In Cont Mode the instrument keeps operating continuously until it is switched off manually or after the maximum operation time has elapsed automatically For adjustment of the maximum operat...

Страница 31: ...stored from now on Further when datalogging is activated simultaneously measurements are saved according to the chosen logging rate Model VD84MIR is equipped with a serial infrared interface If this...

Страница 32: ...d and new measurements are stored according to the chosen logging rate As data memory a battery independent memory IC is used Model VD84MIR is equipped with a serial infrared interface If this data in...

Страница 33: ...ayed Datalogging off means that datalogging is disabled Now the logging rate can be set using the Mode Key 1 6s 16s 64s 10min and off Attention a change of the logging rate setting inevitably results...

Страница 34: ...ff the transmission mode when it is no longer needed 5 3 Infrared Interface The infrared interface of your VD84MIR can be activated for continuous data transmission to a PC online transmission For thi...

Страница 35: ...ion mode when it is no longer needed For longer operation with active IR interface we recommend use of an ex ternal mains adapter accessory AVD8N2 instead of a battery 5 4 Memory Function To activate...

Страница 36: ...rument must be switched off Hold the Mode Key pressed then until the display shows rAtE Then press Mode Key several times until the display shows CAL Adjustment on Atmosphere Pressure After 5 more sec...

Страница 37: ...Mode Adjustment on zero pressure is possible only if the displayed actual pressure is below 4x10 2 mbar Otherwise adjustment is denied and the error message Err displayed 5 6 Pressure Units To set the...

Страница 38: ...unit is turned off automatically in any way switch the VD84 into Configuration Mode For this the instrument must be switched off Hold the Mode Key pressed then until the display shows rAtE Then press...

Страница 39: ...e unit which are caused by contamination or break of filament are not covered by warranty Battery Operation Low battery power is signalized by the batt symbol in the upper left corner of the display O...

Страница 40: ...isplay shows ur pressure under range pressure 10 3 mbar error message Err adjustment done at wrong pressure measurement error out of adjustment range displayed pressure must be 40mbar f atmosphere adj...

Страница 41: ...ng Rate 1 6 s Setting Time 400ms Operating Temperature 0 50 o C Storage Temperature 20 60 o C Power Supply 9V battery accu or 12V plug in supply mini jack plus pole on top Power Consumption ca 110mW c...

Страница 42: ...41 Declaration of Conformity...

Страница 43: ......

Страница 44: ......

Страница 45: ......

Страница 46: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...