If the overload discharge is triggered in this mode, 
the load output will be cut off.  Pressing the Load 
Switch will cause an alarm to sound. 
 
Once system recovers from over discharge or 
overload, press the Load Switch to reset the load 
output function.

3.   Press the Display Button a third time and the LED 

will show the charging current from the solar panel 
to the battery (18A). 
 
Pressing the Switch Button in this mode will change 
the LED display.

 

WARNING! 

Connect Battery Clamps according 

to correct polarity (red for positive and black for 
negative.) Do not short circuit the Battery Clamp.

NOTICE: 

When installing Charge Controller to 

Solar System, always verify that battery voltage and 
solar panel voltage are matching.  The input current 
from the Solar Panel should not exceed the max. 
solar input current limit of the Charge Controller.

NOTE:

 It is normal for the current on LED display 

to change.  Since the battery is changing between 
charging and discharging status when in over-
charger protection, the current variation is normal.

Overcharge Protection 

When the battery voltage is too high, the Controller 
will stop charging to avoid overcharging. When battery 
voltage decreases, the Controller will start charging again.

Discharge Protection 

When battery voltage drops too low, the Controller will 
cut off the power to the load to prevent battery damage. 

Servicing

Procedures not specifically explained in this 
manual must be performed by 
a qualified technician.

TO PREVENT SERIOUS INJURY 
FROM ELECTRIC SHOCK: 
Before service, maintenance or cleaning:

a. 

Dry Charge Controller and outdoor 
wiring thoroughly while wearing 
electrically insulated gloves.

b. 

Cover solar panel with an opaque 
cover, such as a blanket.

c. 

Disconnect solar panel after use.

d. 

Disconnect all batteries after use.

TO PREVENT SERIOUS INJURY FROM 
ELECTRIC SHOCK OR CUTS: 
Do not use damaged Charge Controller. 
If wiring insulation is damaged or 
weathered, solar panel glass is cracked, 

or housing is opened, have the problem corrected 
before further use.

Note:

 It is normal to see up to 20% degradation in 

amorphous silicon solar panel performance within the first 
6 months before the amorphous coating stabilizes. 
 

Cleaning

Clean and inspect all parts of the Solar 
Power System 

MONTHLY

, or more 

frequently to maintain peak efficiency.

1. 

Wear electrically insulated gloves and 
ANSI-approved safety goggles.  

Dry solar 

panel and outdoor wiring thoroughly.

2. 

Cover solar panels with an opaque 
cover, such as a blanket.

3. 

Disconnect solar panel and batteries.

4.  Clean solar panel with mild, non-abrasive 

cleanser and soft cloth and paper towels.  Do 
not clean with brushes or abrasive cleaners.

5.  Inspect the general condition of the Solar Power 

System, including panel, batteries, controllers, 
and mounting connections.  Check for loose 
hardware, wiring insulation damage or weathering, 
cracked glass, open housing, cracked or broken 
parts, loose or corroded contacts, and any other 
condition that may affect its safe operation.

6.  Inspect and maintain batteries according 

to supplier’s instructions.

Adjustment

To increase efficiency:

1. 

In the Winter,

 increase the panel’s angle by 10°.

2. 

In the Summer,

 decrease the angle by up to 10°.

3. 

In the Spring and Fall,

 keep the panel at the angle 

recommended by solar panel’s instruction manual.

Содержание 68738

Страница 1: ...parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2011 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be r...

Страница 2: ...se special caution if working on roof or another high location Keep proper footing and balance at all times Follow ladder supplier s precautions whenever working near or on a ladder 2 Install all sens...

Страница 3: ...reach of children 20 Keep bystanders out of the area during installation 21 Do not install when tired or when under the influence of drugs or medication 22 Use in 12 VDC systems only Battery Precauti...

Страница 4: ...ive and then negative 2 Connect the solar panel ports first positive and then negative 3 Connect the load ports first positive and then negative Wiring Note Only a licensed electrician and a licensed...

Страница 5: ...SHOCK Before service maintenance or cleaning a Dry Charge Controller and outdoor wiring thoroughly while wearing electrically insulated gloves b Cover solar panel with an opaque cover such as a blank...

Страница 6: ...TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMEN...