For technical questions, please call 1-888-866-5797.

Item 68738

10.  Panel must be connected using UL listed outdoor 

rated wire of the correct thickness (gauge) for the 
amperage rating and length (see warning number 
9 also).  Follow the guidelines in the chart below:

Current 

in Amps 

Maximum Length

5' 

10' 

15'

20' 

25'

0-5 

18

6-7 

18

16

18

16

10 

18

16

11-12 

16

14

15 

14

12

18 

18

16

20 

14

12 

10

22-24 

12

30 

16

14 

10

Minimum Wire Gauge

11.  Install an appropriate charge controller/regulator 

to regulate output and prevent damage.  Do not 
attach panel to battery or power grid without proper 
regulator, inverter, and/or charge controller.

12.  Install and use according to applicable 

National Electrical Code (NEC) standards.

13.  This panel is not rated for use as fire-resistant 

roofing.  If installing on a roof, install only over a fire 
resistant roof covering rated for the application.

14.  Verify that installation surface has no hidden 

utility lines before drilling or driving screws.

15.  Install only according to these instructions.  

Improper installation can create hazards.

16.  Wear ANSI-approved safety goggles and heavy-

duty work gloves during installation.  Do not 
wear jewelry or metal watches when working 
near solar panels, wiring or batteries.

17.  Handle panel with care.  Glass may break or a 

sharp edge may be exposed during movement.

18.  Keep installation area clean and well lit.

19.  Install out of reach of children.

20.  Keep bystanders out of the area during installation.

21.  Do not install when tired or when under 

the influence of drugs or medication.

22.  Use in 12 VDC systems only.

Battery Precautions

1. 

Wear splash-resistant ANSI-approved 
safety goggles and electrically insulated 
gloves while working near batteries.

2. 

Use an appropriate charge controller 
whenever connected to battery.

3.  Charge, store, and maintain batteries 

according to supplier’s instructions.

Service Precautions

1. 

Before service, maintenance, or cleaning:

a. 

Dry solar panels and outdoor 
wiring thoroughly while wearing 
electrically insulated gloves.

b. 

Cover all solar panels with an opaque 
cover, such as a blanket.

c. 

Disconnect all solar panels.

d. 

Disconnect all batteries.

2. 

Do not service during rain, fog, or 
any other wet/humid weather.

3. 

Do not stand on or otherwise 
apply pressure to panel.

4.  Do not allow children to play with or 

near this or electrical components.

5.  Inspect at least monthly; do not use if damaged, 

parts are loose, water is found inside the 
housing, electrical insulation is cracked or 
damaged, or connections are loose.

6.  Maintain product labels and nameplates.  

These carry important safety information.  
If unreadable or missing, contact 
Harbor Freight Tools for a replacement.

  SAVE THESE 

INSTRUCTIONS.

Specifications

Max. Input Wattage

360 Watt (for 12V panel)

Max. Input Voltage

50V

Max. Input Amps

30A

Rated Output

12VDC

Overcharge Voltage

14.5V + 0.4V

 

Note:

 Output will decrease as the panel gets hotter 

than room temperature (~70° F).  Angle, solar intensity,  
cloud cover and other factors will effect output.

Содержание 68738

Страница 1: ...parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2011 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be r...

Страница 2: ...se special caution if working on roof or another high location Keep proper footing and balance at all times Follow ladder supplier s precautions whenever working near or on a ladder 2 Install all sens...

Страница 3: ...reach of children 20 Keep bystanders out of the area during installation 21 Do not install when tired or when under the influence of drugs or medication 22 Use in 12 VDC systems only Battery Precauti...

Страница 4: ...ive and then negative 2 Connect the solar panel ports first positive and then negative 3 Connect the load ports first positive and then negative Wiring Note Only a licensed electrician and a licensed...

Страница 5: ...SHOCK Before service maintenance or cleaning a Dry Charge Controller and outdoor wiring thoroughly while wearing electrically insulated gloves b Cover solar panel with an opaque cover such as a blank...

Страница 6: ...TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMEN...

Страница 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 68738 Assembly Diagram...

Страница 8: ...n or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING...

Отзывы: