The mount bracket is for the use of both Wall mount (Figure 1) and Hanging mount (Figure 2). 

 

Position the bracket holders and fix it by means of the provided M8 screws, 61 kgf-cm. 

 

Secure the Wall/Hanging mounting bracket to the structure by using four fasteners

 (

not provided).   

 

The angle of lighting fixture can be adjusted.

 

 
 
 
 
 
 
 
 
 

 

 

5.2

 

アース線

Ground

 wire 

 

外部アーススクリューの位置は右の写真の赤い円で示しております

  

 

外部アース線の設置と接続端子タイプは右図の様に“

U

”,”

O

”です。

 

 

アース線の断面積

 =

 4 mm ²

18 

AWG

、最大

 LED 

電流

 = 

1

a;

 

@V = 

110

Vac-

10

%

 

 

アースネジおよびワッシャーはステンレス鋼である。

 

 

適合ネジ

: M

4

 

 

締め付けトルク

kgf-cm 

 

ワイヤーが確実に結ばれていることを確認します。

 

 

External earth screw location as showing in the Red Circle of right pictures. 

 

Ground wire cross-sectional area = 4 mm²

18 AWG, max LED current = 1A; @V = 110Vac-10%. 

 

The external ground wire installation and terminal type as show the right pictures. 

 

Both

 

ground screw and washer material is stainless steel. 

 

Screw hole Spec: M4, 

 

Torque requirement: 7 kgf-cm. 

 

Ensure wire is tied assured. 

5.3

 

使用

/

運行開始

Putting into Service 

動作する前に、以下の手順に従って確認してください。

 

Before putting into operating, it’s necessary to ensure that: 

 

 

 

照明が正しく取り付けられていること。

 

 

接続が正しく行われました。

 

 

ケーブルが正しく挿入されている。

 

 

電圧が正しいこと。

 

 

 

Содержание L1601C

Страница 1: ...l L1601C Revision Level 02 Date 2018 05 28 Contents 1 General Safety Instructions 2 2 Intended Field of Application 3 3 Technical Data 3 4 4 Dimension 4 5 Assembly and Installation 4 6 6 Maintenance 6...

Страница 2: ...Verify the implementation of safety instructions WARNING This manual contains basic safety instructions to be observed during installation operation and maintenance of the apparatus and for properly...

Страница 3: ...plosion Protection Dust Explosion Protection IECEx Gas Explosion Protection Dust Explosion Protection IECEx UL 18 0060X Issue 0 Ex nR IIC T6 Gc Ex tb IIIC T85 C Db DEMKO 18 ATEX 1945X Rev 0 II 3 G Ex...

Страница 4: ...y to the Pressure Nut to compress the Sealing Ring Fitting Cable 18 3C AWG SOOW 1 3 m length Size of Sealing Ring Fitting Cable ID 9 0 L 15 mm OD 8 0 9 0 Mounting Type Wall Hanging mounting 4 mm Dimen...

Страница 5: ...adjusted 5 2 Ground wire U O 4 mm 18 AWG LED 1a V 110Vac 10 M4 7 kgf cm External earth screw location as showing in the Red Circle of right pictures Ground wire cross sectional area 4 mm 18 AWG max LE...

Страница 6: ...ed are promptly detected To check as part of the maintenance schedule as following Cracks or damages on the glass cover and or on the enclosure Condition of the connecting cables Screws of the mountin...

Страница 7: ...arton box Transport Shock free in its original carton do not drop and handle carefully Store Store in a dry place in its original packaging Disposal Ensure environmentally friendly disposal of all com...

Отзывы: